Figure D-4. Functional Test Setup (With High Temp Accelerometer And Photocell - Honeywell Chadwick-Helmuth 8500C Maintenance Manual

Balancer/analyzer system
Table of Contents

Advertisement

Appendix D - 8520CS Signal Selector
POWER SUPPLY 9100A
POWER
10494
CALIBRATOR 11A
NOTE: 11B users, bypass
mag pulse doubler and
connect magnetic pickup
cable directly to channel A
on 8520C. This simulates
11A use.
Figure D-4. Functional Test Setup (with High Temp Accelerometer and
g.
Adjust pot next to 1800 CAM RATE switch position until outside ring on rotor disk
appears froze in place under 60 Hz light
h.
Press BALANCE key on 8500C/C+.
i.
Press SETUP key.
j.
Key in 900 with numeric keys in BALANCE FREQUENCY field.
NOTE: To undo mistaken entries, press the RESTORE soft key.
k.
On same line, press right arrow key twice to select last number (calle "times factor") with
arrow keys.
l.
Key in 2 as new times factor. This entry now reads: x2.
m.
Select <AUTO STOP> field with arrow keys and press CHANGE soft key to select MAN
STOP.
n.
Select PHASE UNITS field with arrow keys.
o.
Press CHANGE soft key to select <DEGREES>.
1
Attention, users outside U.S.: The 11A Calibrator can also be calibrated under 50Hz light. For 1714
rpm and 923 rpm cam rates, inner two rings on rotor disk are used. Remember to enter half these rates
in 8500C/C+ setup screen, when called for in the following steps.
D-8 Chadwick-Helmuth A Business Unit of Honeywell International, Inc.
CABLE 10813
CABLE 10700
BALANCER
ACCELEROMETER
ADAPTER BRACKET
CABLE 10700
10494
10200 PHOTOPROBE
CABLE 14883
NOTE: The calibrator must have no more than one screw installed on its rotor
disk when used with the 8500C; however, the calibrator was designed to have at
least two screws 180 degrees apart. To simulate a second screw, enter the
actual rpm (half the "CAM RATE") as the balance frequency and "2" as the times
factor in the 8500C balance setup display. For example, if the CAM RATE is
900, enter "450" as the balance frequency and "2" as the times factor.
Photocell)
8500C BALANCER/ANALYZER
PRINT
A
SHOW/HIDE
B
MORE/KEYS
C
BALANCE
D
:
SPECTRUM
J
#
TRACK
P
%
1
2
3
A
1
.
BALANCER/ANALYZER
START
W
X
STOP
Z
Y
HELP
STATUS
2
3
1
G
I
H
.
E
F
4
5
6
LOAD
SETUP
M
N
O
M O D E L 8 5 0 0 C
-
K
<
L
8
9
7
S
T
U
CHADWICK
HELMUTH
STORE
ANNOTATE
E L
M O N T E ,
C A L I F O R N I A
/
0
Q
>
R
V
4
7
10
5
8
11
9
12
6
B
C
D
8520CS SIGNAL SELECTOR

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Chadwick-helmuth 8500c+

Table of Contents