Figure 5-6. Functional Test Setup (With Tracker); Figure 5-7. Special Overlay - Honeywell Chadwick-Helmuth 8500C Maintenance Manual

Balancer/analyzer system
Table of Contents

Advertisement

.
POWER SUPPLY 9100A
POWER
CALIBRATOR 11A
NOTE: 11B users, bypass
mag pulse doubler and
connect magnetic pickup
cable directly to channel A
on 8520C. This simulates
11A use.

Figure 5-6. Functional Test Setup (with Tracker)

CABLE 10813
BALANCER
MAG PICKUP 3030
CABLE 10808
CABLE 12700
NOTE: The calibrator must have no more than one screw installed on its rotor
disk when used with the 8500C; however, the calibrator was designed to have at
least two screws 180 degrees apart. To simulate a second screw, enter the
actual rpm (half the "CAM RATE") as the balance frequency and "2" as the times
factor in the 8500C balance setup display. For example, if the CAM RATE is
900, enter "450" as the balance frequency and "2" as the times factor.

Figure 5-7. Special Overlay

8500C BALANCER/ANALYZER
BALANCER/ANALYZER
PRINT
A
SHOW/HIDE
B
MORE/KEYS
C
BALANCE
HELP
D
:
E
SPECTRUM
LOAD
J
#
K
TRACK
STORE
Q
P
%
1
2
3
A
8520CS SIGNAL SELECTOR
8500C/8500C+ System Maintenance Manual 5-11
Functional Tests
START
W
X
STOP
Y
Z
STATUS
1
2
3
I
G
H
F
.
4
5
6
SETUP
M
N
O
M O D E L 8 5 0 0 C
-
<
L
8
9
7
S
T
U
CHADWICK
HELMUTH
ANNOTATE
E L M O N T E ,
C A L I F O R N I A
>
/
0
R
V
4
7
10
5
8
11
6
9
12
B
C
D

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Chadwick-helmuth 8500c+

Table of Contents