Emerson Fisher 4320 Instruction Manual Supplement page 3

Atex hazardous area approvals wireless position monitor
Hide thumbs Also See for Fisher 4320:

Advertisement

Instruction Manual
D104306X012
Figure 2. Installation Drawing for Battery Module Assembly; See Notes in Figure 1
HART COMM TERMINALS
WP1/WP2
GE59530-B, sheet 1
Figure 3. Installation Drawing for External Power Option; See Notes in Figure 1
GE59530-B, sheet 2
BATTERY
MODULE
ASSEMBLY
MAIN BOARD
ASSEMBLY
HART COMM TERMINALS
WP1/WP2
POWER TERMINAL
(J5)
4320 Wireless Position Monitor - ATEX
HAZARDOUS LOCATION NON-HAZARDOUS LOCATION
INTRINSICALLY SAFE
CLASS I DIV 1 GP ABCD
CLASS I, ZONE 0 GP IIC
4320 POSITION MONITOR
HART COMM TERMINALS
(BATTERY MODULE - WP1 / WP2)
Ui = 6.0 V
Uo = 6.0 V
Ii = 5 mA
Io = 14 mA
Pi = 30 mW
Po = 84 mW
Co = 39 mf
Ci = 2.5 nF
Li = 0 mH
Lo = 150 mH
HAND HELD
HAZARDOUS LOCATION NON-HAZARDOUS LOCATION
INTRINSICALLY SAFE
CLASS I, DIV 1 GP ABCD
CLASS I, ZONE 0 GP IIC
4320 POSITION
POWER
MONITOR
(J5)
POWER TERMINAL
Ui = 28 VDC
Ii = 100 mA
Pi = 1 W
Ci = 78 nF
Li = 2.63 mH
HART COMM TERMINALS
(WP1 / WP2)
Ui = 6.0 V
Uo = 6.0 V
Ii = 5 mA
Io = 14 mA
Pi = 30 mW
Po = 84 mW
Co = 39 μf
Ci = 2.5 nF
Li = 0 mH
Lo = 150 mH