42
en | Network
Select the type of Ethernet link for the interface for the camera connected to the port labeled
PoE on the PCBA of VIDEOJET connect 7000.
Depending on the device connected, it may be necessary to select a special operation type.
Options are:
If necessary, select the type of Ethernet link for the interface for the device connected to the
port labeled ETH 1 on the PCBA of VIDEOJET connect 7000.
Depending on the device connected, it may be necessary to select a special operation type.
Options are:
Note: Do not select a baud rate for this port unless a device is connected to this port on
VIDEOJET connect 7000.
If necessary, select the type of Ethernet link for the interface for the device connected to the
port labeled ETH 2 on the PCBA of VIDEOJET connect 7000.
Depending on the device connected, it may be necessary to select a special operation type.
Options are:
Note: Do not select a baud rate for this port unless a device is connected to this port on
VIDEOJET connect 7000.
Network MSS (Byte)
You can set the maximum segment size for the IP packet's user data. This gives you the option
to adjust the size of the data packets to the network environment and to optimize data
transmission. Please comply with the MTU value of 1,514 bytes in UDP mode.
iSCSI MSS (Byte)
You can specify a higher MSS value for a connection to the iSCSI system than for the other
data traffic via the network. The potential value depends on the network structure. A higher
value is only useful if the iSCSI system is located in the same subnet as the camera.
Network MTU (Byte)
The value in the field defaults to 1514.
12.2

DynDNS

Enable DynDNS
DynDNS.org is a DNS hosting service that stores IP addresses in a database ready for use. It
allows you to select the camera via the Internet using a host name, without having to know the
current IP address of the unit. You can enable this service here. To do this, you must have an
account with DynDNS.org and you must have registered the required host name for the unit on
that site.
2019-08 | 1.7 | F.01U.291.524
Auto
10 Mbps HD (half duplex)
10 Mbps FD (full duplex)
100 Mbps HD (half duplex)
100 Mbps FD (full duplex)
Auto
10 Mbps HD (half duplex)
10 Mbps FD (full duplex)
100 Mbps HD (half duplex)
100 Mbps FD (full duplex)
Auto
10 Mbps HD (half duplex)
10 Mbps FD (full duplex)
100 Mbps HD (half duplex)
100 Mbps FD (full duplex)