Machine Control Panels
The module is connected to the logic circuit board via the internal shift register
bus. The key states are sent to the master control via field bus. The LEDs are
triggered via field bus by the master control.
The address allocation of keys and LEDs is described in
12.5.1 "Keypad" on page
12.3.6 Override rotary switch
Fig. 12-8: Override rotary switch
Feed override
(Upper rotary switch)
Spindle override
(Lower rotary switch)
Tab. 12-2: Override rotary switch
The module is connected to the logic circuit board via the internal shift register
bus. The switch positions of both rotary switches are transmitted to the master
control via the field bus.
The address allocation of the module is described in
"Override rotary switch" on page
12.3.7 22.5 mm switching elements
The 22.5 mm switching elements (① in the following figure) are pro-
vided on both the machine control panels IndraControl VAM 15.1
and IndraControl VAM 21.1.
The four additional combine pre-cut-outs for 16 mm/22.5 mm
switching elements (② in the following figure) are only provided on
the IndraControl VAM 15.1.
DOK-SUPPL*-VAM*15*21*1-IT02-EN-P
41.
24 switch positions
16 switch positions
42.
Bosch Rexroth AG
Device description
chapter
chapter 12.5.2
37/53