Voltage supply
Logic supply U
L
Current consumption from U
Input supply and output supply U
Current consumption from U
Fuse for U
and U
L
M
Reverse voltage protection
Tab. 7-2: Basic device – Electrical data
D-SUB socket, 25-pin
RJ45 sockets
Connector strips by Weidmüller, 4-pin, 6-pin and 8-pin
Tab. 7-3: Connection method

7.2 E-STOP button

Only 24 V (protective extra-low voltage) may only be connected to
the E-STOP button!
E-STOP button acc. to DIN EN 60947-5-5
Name
Connection voltage
Max. current
DOK-SUPPL*-VAM*15*21*1-IT02-EN-P
IndraControl VAM 15.1/VAM 21.1
Electrically isolated
24 V DC (19.2 V to 30 V), PELV
Use for example the 24 V industrial power supply
unit VAP01.1H-W23-024-010-NN with the part
number R911171065 (for specifications on the
operating instructions of the power supply unit, re-
fer to
0.3 A typ.
L
24 V DC (19.2 V to 30 V), PELV
M
Use for example the 24 V industrial power supply
unit VAP01.1H-W23-024-010-NN (part number
R911171065)
3.5 A max.
M
SMD fuse 4 A
Integrated
E-STOP button, tamper-proof with rotary release;
equipped with:
PELV/SELV
0.5 A
"Related documents" on page
2 × standard auxiliary switches with forced
opening
1 × standard auxiliary switch N/O contact