Installation Tips to Ensure Proper Performance

Before installing, read all directions carefully and contact your dealer for installation support.
WARNING
• Do not exceed maximum operating pressure of 50 psi.
• Do not install automatic or fast shut off valves
downstream of feeder.
• Always install the New Water Cycler AFTER the
heater (if applicable) on the return line.
• Always install any additional sanitizing equipment
AFTER and NEVER BEFORE the New Water Cycler
is installed on the return line.
1) If using a multi-speed pump, run
pump for at least 6 hours per day at
high speed (at least 40 gpm).
If the pump will run on low speed 24
hours per day or less than 6 hours per
day on high speed, you must bleed the
air while the pump is on by unscrewing
either the cap knob or back knob until
water appears. Then screw the knob
back in. Repeat this process each time
the cap is removed for any reason.
2) Install Cycler with 4-8 psi back pressure.
Lower back pressures could result in under
chlorination. Change the eyeball fi ttings in
the return jets to a smaller size to increase
back pressure. Contact King Technology at
800-222-0169 for a specially designed
Cycler pressure gauge to determine back
pressure at pool start-up.
3) Special installation Requirements:
IMPORTANT: Over chlorination or damage to the New
Water Cycler or other equipment could result if special
installations A, B or C are not used in these situations:
• If water fl ow is higher than 80 gallons per minute (gpm),
see diagram A.
• If an in-fl oor cleaner is included with pool,
see diagram B, with two options. Preferred
installation is Option 1 with two separate lines.
• If set-up is a pool and spa combination with
common equipment, see diagram C.
Questions? Call Customer Service at 800-222-0169
Monday thru Friday, 8 am to 5 pm central standard time.
6
A. With High Flow Rate (greater than 80 gpm) Install
T-fi ttings exactly as shown.
SUCTION
FROM
POOL/SPA
B. With In-Floor Cleaner - TWO OPTIONS
OPTION 1- A Two-Line Installation
The best option is to have two lines. One line with pump, fi lter, heater and
New Water Cycler and a second line with a separate pump for the in-fl oor
cleaning system (fi lter optional).
Line 1
Flow
Line 2
Flow
PN #01-22-4000
OPTION 2 - A 3-Way Valve Installation
C. Pool and Spill-over Spa Combination
SUCTION
FROM
POOL/SPA
CHECK
VALVE
HEATER
PUMP
POOL WATER LEVEL
POOL WATER LEVEL
PUMP
POOL WATER LEVEL
3-way manual valve or 3-way motor valve plus controls
NEW WATER
CYCLER
9
9
9
PUMP
9
POOL WATER LEVEL
CHECK VALVE
PUMP
NEW WATER
CYCLER
NEW WATER CYCLER
TO POOL
NEW WATER
CYCLER
POOL RETURN
IN-FLOOR
CLEANER VALVE
POOL WATER LEVEL
IN-FLOOR
CLEANER VALVE
9
3-WAY VALVE

Advertisement