King Technology Perform-Max 920 Manual

Pool sanitizer

Advertisement

Quick Links

PERFORM-MAX
POOL SANITIZER
Models 920, 940 & 980 (In-line)
Model 960 (Off-line)
In Ground Model 940
Above Ground Model 920
Customer Service 800-222-0169
www.KingTechnology.com
1

Advertisement

Table of Contents
loading

Summary of Contents for King Technology Perform-Max 920

  • Page 1 PERFORM-MAX ™ POOL SANITIZER Models 920, 940 & 980 (In-line) Model 960 (Off-line) In Ground Model 940 Above Ground Model 920 Customer Service 800-222-0169 www.KingTechnology.com...
  • Page 2: Table Of Contents

    Refilling Chemicals Changing Chemicals (i.e. switching from chlorine to bromine) Setting Control Dial Replacing Control Dial O-rings Replacing Cap O-rings & Knobs Winterizing For Proper Performance Warranty For information on King Technology’s entire product line, visit our website at www.KingTechnology.com...
  • Page 3: Introducing Perform-Max

    Perform-Max™ Thank you for choosing the Perform-Max Pool Sanitizer for you pool. Perform-Max precisely meters chlorine at a consistent rate so you are ensured of a properly sanitized pool with less work and more time to enjoy. In-line unit for Off-line unit for in ground In-line unit for in ground pools...
  • Page 4: Installation Introduction

    Above Ground Pools Perform-Max Installation Installation Tips: Model #920 In-line for above ground pools up to 25,000 gallons using chlorine and up 1/4" to 15,000 gallons using bromine. Installation instructions are on pages 7 and 8. DO NOT INSTALL OFF-LINE. "...
  • Page 5: Parts List Model 920

    Parts List • Model 920 SILICONE LUBRIC ANT Optional part- not included Included with Above Ground Model 920 Replacement Parts for Above Ground Model 920 REF. # DESCRIPTION QTY. INCLUDED REF. # PART NO. DESCRIPTION 1 & 2 Cap w/O-Ring 1 &...
  • Page 6: Parts List Models 940, 960, 980

    Parts List Models 940, 960, 980 8 & 9 SILICONE LUBRICANT P O O L S AN ITI ZER INCLUDED WITH • Models 940, 960 and 980 REPLACEMENT PARTS • Models 940, 960 and 980 REF. # DESCRIPTION QTY. INCLUDED REF.
  • Page 7: Base Installation Model 920

    Above Ground, Base Installation - Model 920 TOOLS NEEDED Screwdriver • Install after all equipment and as far as possible from heater. Pipe Wrench PUMP • Any additional sanitizing equipment that is installed with Perform-Max must be installed after FILTER Perform-Max (never before) on the return line to the pool.
  • Page 8: Filter Installation Model 920

    Above Ground, Filter Installation - Model 920 TOOLS NEEDED Screwdriver Pipe Wrench MATERIALS NEEDED Screw one end of nipple Pipe Thread Tape into the filter return. or Sealant Apply pipe thread tape or Screw either side of sealant to each threaded end Perform-Max on to open Hand tighten.
  • Page 9: In-Line Installation Model 940

    In Ground, In-line Installation - Model 940 TOOLS NEEDED Pipe Wrench • Install after all equipment and as far as possible from heater. • Any additional sanitizing equipment that is installed with Hacksaw Perform-Max must be installed after Perform-Max (never before) on the return line to the pool.
  • Page 10: Off-Line Installation Model 960

    In Ground, Off-line Installation - Model 960 TOOLS NEEDED Screwdriver SCOOPS • Install after all 2” – 36” APART equipment and as far as Pipe Wrench possible from heater. • Any additional sanitizing equipment that is installed Battery with Perform-Max must be When insufficient room for an in-line application, install off-line in Operated Drill installed after Perform-Max...
  • Page 11 When pipe is Cut tubing totally dry, drill two to size 19/32” or 5/8” for each holes, between Perform- 2” - 36” apart, on the return line. Be connection careful not to go and attach through other side one to of pipe.
  • Page 12: Troubleshooting

    NEVER ADD cap knob (see page 17 for help in correcting this situation. SHOCK IN OR NEAR THE directions). 7. Contact King Technology’s SKIMMER. Reset dial 1/2 4. Try bleeding the air, soaking Customer Service Department setting higher than before tablets for greater output.
  • Page 13: Refilling Chemicals

    Refilling USE ONLY slow dissolving trichloro-s-triazinetrione (trichlor) tablets or pucks or bromine Chemicals tablets or sticks in the Perform-Max. NEVER MIX CHEMICALS. DO NOT USE ...CALCIUM HYPOCHLORITE, FAST DISSOLVING TRICHLOR OR ANY GRANULAR OR LIQUID MATERIAL IN THE PERFORM-MAX. Use of these products could result in over chlorination, bleached liners, unsafe pool conditions, fire or explosion.
  • Page 14: Setting Control Dial

    Setting Control Dial When using slow dissolving trichlor, the Perform-Max should be operated based on its normal erosion design where only the bottom layer of tablets are wetted. This provides better controllability and longer lasting sanitation per refil. When using bromine, the Perform-Max should be operated as a soaking feeder as this chemical works best when all tablets are wetted. Therefore bleeding the air on these units is recommended when using bromine.
  • Page 15: Replacing Control Dial O-Rings

    Replacing Control Dial O-Rings Model 920 Models 940/960/980 Center of locking pin Center of locking pin 1. In the back of the 1. Using a needle nose pliers, Perform-Max depress center find the snap ring tail located of locking pin with a finger at approximately the 5 o’clock and pull pin out of dial.
  • Page 16: Replacing Cap O-Rings & Knobs

    Winterizing Replacing Cap O-ring 1. Hold cap in front of you Models 940, 1. Operate Perform- upside down with the o-ring 960, 980 Max until empty of all groove facing up. Place one chemical. When empty, end of o-ring into cap groove set control dial to at the point closest to you.
  • Page 17: For Proper Performance

    Perform-Max and a second line with a separate pump for the in-floor fittings in the return jets to a smaller cleaning system (filter optional). size to increase back pressure. Contact King Technology at 800-222- Perform-Max ✙ Line 1 0169 for a cap tapped for a pressure ✙...
  • Page 18: Warranty

    DAMAGES WILL NOT EXCEED THE PURCHASE PRICE OF THE the product or operation or installation in a manner contrary UNIT. IN NO EVENT WILL KING TECHNOLOGY BE LIABLE FOR to the accompanying instructions. This warranty also excludes ANY INCIDENTAL, CONSEQUENTIAL, SPECIAL OR PUNITIVE all costs arising from the installation, adjustment, removal or DAMAGES FROM ANY CAUSE.

This manual is also suitable for:

Perform-max 940Perform-max 960Perform-max 980

Table of Contents