King Technology New Water Series Instruction Manual

Chlorine pool-care cycler system

Advertisement

Quick Links

NEW WATER
Cycler
®
Instruction Manual
Chlorine Pool-Care System
Model 400/430 for pools up to 40,000 gallons
Model 120 for pools up to 25,000 gallons
WARNING
Customer Service 800-222-0169
To minimize the risk of serious injury, death or
damage, before installing or first using this
kingtechnology.com
equipment, read Instruction Manual and all safety
labels and follow all safety instructions and
precautions. Save manual for future reference.
Ver la versión en español de este manual en kingtechnology.com/brands/new-water
1

Advertisement

Table of Contents
loading

Summary of Contents for King Technology New Water Series

  • Page 1 NEW WATER Cycler ® Instruction Manual Chlorine Pool-Care System Model 400/430 for pools up to 40,000 gallons Model 120 for pools up to 25,000 gallons WARNING Customer Service 800-222-0169 To minimize the risk of serious injury, death or damage, before installing or first using this kingtechnology.com equipment, read Instruction Manual and all safety labels and follow all safety instructions and...
  • Page 2: Table Of Contents

    Step 4: Routine Pool Care Winterizing Troubleshooting Parts List Model 120 Parts List Models 400/430 Maintenance - Replacing Control Dial O-Rings Maintenance - Replacing Cap O-Rings and Knobs Warranty For information on King Technology’s entire product line, visit our website at kingtechnology.com...
  • Page 3: New Water Introduction

    Thank you for choosing New Water. This system will maintain a clean, clear swimming pool while you spend less time on maintenance and more time having fun! There are three models to choose from: New Water Cycler 400/430 The water treatment center that controls the fl ow of water to the New Water Cycler Pac.
  • Page 4: Notes And Safety Information

    Should further informa- follows the instructions and safety precautions. tion be desired or should particular issues arise which are not covered suffi ciently in this manual, contact King Technology at • Keep the instructions nearby and available for reference 800-222-0169.
  • Page 5: Safety Labels On Cycler

    Safety Label on Cycler Review this label before installing or operating this Cycler. Contact King Technology at 800-222-0169 if this label is missing from your New Water Cycler. Fire, explosion and high pressure hazards To minimize the risk of serious injury, death or property damage while using the New Water Cycler: a Read, understand and follow all instructions and safety precautions in the manual, and on this Cycler and on any label for chemicals used with this Cycler including New Water Cycler Pacs.
  • Page 6: Installation Tips To Ensure Proper Performance

    Lower back pressures could result in under chlorination. Change the eyeball fi ttings in the return jets to a smaller size to increase Line 2 IN-FLOOR back pressure. Contact King Technology at CLEANER VALVE 800-222-0169 for a specially designed Flow PUMP Cycler pressure gauge to determine back pressure at pool start-up.
  • Page 7: Filter Flex-Hose Installation Model 120

    To avoid over or under chlorination, replace eyeball fi ttings in the return jets to a smaller or larger size to adjust back pressure. For best results use King Technology’s pressure gauge, order part number ® 01-22-4000. HOSE ADAPTER To prevent damage to heaters...
  • Page 8: Base Flex-Hose Installation Model 120

    FLEX HOSE fi ttings in the return jets to a smaller or larger size to adjust back pressure. For best results HOSE ® use King Technology’s pressure ADAPTER HOSE gauge, order part number ADAPTER 01-22-4000. TO POOL...
  • Page 9: Hard-Plumbed Installation Model 120

    Hard-Plumbed Installation - Model 120 TOOLS NEEDED Pipe Wrench ® Hacksaw The New Water Cycler should always be installed between Do NOT install in copper pipe as the fi lter and pool (or between heater and pool if applicable). Tape chemical corrosion may lead to pipe Never install New Water Cycler before the heater or failure.
  • Page 10: In-Line Installation Model 400

    If you have C emen t questions about stability, please contact your dealer To prevent damage to or King Technology. Following primer directions, heaters or fi lters, see your Insert PVC pipe into male dealer about installing a...
  • Page 11: Off-Line Installation Model 430

    TOOLS NEEDED Off-line Installation - Model 430 Screwdriver The New Water Cycler should always be installed between SCOOPS 2” – 36” APART the fi lter and pool (or between Pipe Wrench heater and pool if applicable). Never install New Water Cycler ®...
  • Page 12 Phillips pan head screws, one in front and one in back. If you have questions about stability, please contact your dealer or King Technology. SCOOPS 2” – 36” APART To prevent damage to heaters or fi lters, see your dealer about installing a corrosion resistant check valve ®...
  • Page 13: Step 1: Preparing The Pool

    Step 1: Preparing the Pool Make sure the pool has adequate Check for metals in the pool such circulation. The total volume of pool as iron or copper. Before attempting water must completely circulate Metal water balance, these should be through the pump and fi lter at least removed.
  • Page 14 Continue... Step 1: Preparing the Pool For best results in achieving water balance, follow Initially shock the pool with chlorine shock only to rid the water of contaminants and establish a chlorine steps 5a through 5e in order. residual. Always follow the manufacturer’s directions carefully.
  • Page 15: Step 2: Putting The System To Work

    Step 2: Putting the System to Work DANGER Avoid a If openings are pinched Never use fast dissolving chlorine tablets, liquid bleach, pinched or calcium hypochlorite in the New Water Cycler. together, open with fi ngers or opening. re-cut closer to the colored A correct screens inside New Water WARNING...
  • Page 16: Step 3: Setting The Control Dial

    Step 3: Setting Control Dial This system is designed to work effectively with a variety of pool equipment as long as the following procedures are followed. Set control dial on New Water Cycler by matching up the parameters of your pool on the chart below. THIS IS A STARTING POINT ONLY and may need to be adjusted to fi t your individual pool needs.
  • Page 17: Step 4: Routine Pool Care

    Step 4: Routine Pool Care Shock the pool every week or as Run fi ltration system enough hours needed with a non-chlorine or to circulate all water 1 to 2 times per day. More than that could result in chlorine shock. over chlorination.
  • Page 18: Winterizing

    Winterizing (Model 120 or Model 400/430) Remove Pac. Turn pump off. Turn dial to 0 Turn dial to minimum ® Model 120 Model 400/430 Remove cap. Model 120 Model 400/430 If New Water Cycler Pac still contains chlorine, wrap in plastic bag and store in shed or cool, dry, well-ventilated location away from children,...
  • Page 19: Troubleshooting

    Troubleshooting For help in troubleshooting, call King Technology at 800-222-0169. Problem Remedy 1. Make sure your fi ltration 3. Make sure the pool is 5. Make sure pool has a What do I do system is working properly (i.e. properly balanced free chlorine reading of (see page 13).
  • Page 20: Parts List Model 120

    Parts List • Model 120 SILICONE LUB RICANT 9 & 10 Included with New Water 120 Replacement Parts for New Water 120 REF. # DESCRIPTION QTY. INCLUDED REF. # PART NO. DESCRIPTION 1 & 2 Cap w/O-Ring 1 & 2 01-22-1410 Cap w/O-Ring Body...
  • Page 21: Parts List Models 400/430

    Parts List • Models 400 and 430 INCLUDED WITH • Model 400 and 430 REF. # DESCRIPTION QTY. INCLUDED 1 & 2 Cap w/O-Ring Body Pressure Relief Valve SILICONE 5, 6, 7 Control Dial with O-Rings LUBRICANT 8 & 9 Knob with O-Ring Cap/Control Dial Tool Silicone Lubricant...
  • Page 22: Maintenance - Replacing Control Dial O-Rings

    Cycler Maintenance Replacing Control Dial O-Rings • Model 120 • Models 400/430 Center of locking pin In the back of the New Water Using a needle nose pliers, Cycler depress center of fi nd the snap ring tail located locking pin with a fi nger and at approximately the 5 o’clock pull pin out of dial.
  • Page 23: Maintenance - Replacing Cap O-Rings And Knobs

    Cycler Maintenance continued... Replacing the Cap O-Ring Model 120 Models 400/430 Remove old O-ring. Remove old O-ring. Top half of Top half of groove groove. Place new O-ring in bottom half of groove. Place new O-ring in bottom half of groove. Bottom half of groove.
  • Page 24: Warranty

    Limited One-Year Warranty King Technology, Inc. will warrant this unit with a complete replace- 3. Any express warranty not provided for herein, and any remedy for ment for the original purchaser, should it prove defective by reason breach of warranty or breach of contract which, but for this provision,...

Table of Contents