Table 90. Electrical
(continued)
Electrical characteristics
Maximum measured power
Minimum kVA
Maximum kVA
Minimum thermal output
Maximum thermal output
Input voltage (low range)
Input voltage (high range)
Frequency (low range)
Frequency (high range)
1. Power consumption and heat output vary depending on the number and type of optional features that are
installed and the power-management optional features that are in use.
Table 91. Environmental requirements
Environment
Temperature
Humidity range
Maximum dew point
Maximum altitude
Table 92. Noise emissions
Declared A-weighted sound power level,
Product description
L
One hard disk drive
configuration
Note:
1. These levels were measured in controlled acoustical environments according to the procedures specified by the
American National Standards Institute (ANSI) S12.10 and ISO 7779 and are reported in accordance with IS) 9296.
Actual sound-pressure levels in a given location might exceed the average values stated because of room
reflections and other nearby noise sources. The declared sound-power levels indicate an upper limit, below
which a large number of computers will operate.

7042-C08 Hardware Management Console specifications

Hardware specifications for model 7042-C08 provide detailed information for your Hardware
Management Console (HMC), including dimensions, electrical, power, temperature, and environmental
specifications.
The HMC controls managed systems, including the management of logical partitions and the use of
capacity on demand. Using service applications, the HMC communicates with managed systems to
detect, consolidate, and send information to IBM for analysis. The HMC provides service technicians with
diagnostic information for systems that can operate in a multiple-partitioned environment.
Use the following specifications to plan for your HMC.
Allowable operating
10°C - 32°C (50°F - 89.6°F)
8% - 80%
24°C (75°F)
1
(bels)
WAd
Operating
5.2
Properties
523 W
0.106
0.352
630 BTU/hr
1784 BTU/hr
100 - 127 V ac
200 - 240 V ac
47 Hz to 53 Hz
57 Hz to 63 Hz
Nonoperating
8% - 80%
27°C (80.6°F)
2133 m (7000 ft) (Server off)
Declared A-weighted sound pressure level,
L
(dB)
pAm
Nonoperating
Operating
4.8
Nonoperating (shipping)
-40°C to 60°C (-40°F to
140°F)
29°C (84.2°F)
Nonoperating
37
33
Site and hardware planning