Safety compliance: UL 60950-1, 2nd Edition, 2014-10-14; CAN/CSA C22.2 No. 60950-1-07, 2nd Edition,
2014-10, IEC 60950-1:2005 (Second Edition); Am1:2009 + Am2:2013; EN 60950-1:2006 + A1:2010 + A11:2009
+ A12:2011 + A2:2013
Rack switch specifications
Rack switch specifications provide detailed information for your IBM BNT RackSwitch, including
dimensions, electrical, power, temperature, environment, and service clearances.
Select the appropriate models to view the specifications for your rack switch.
G8052R RackSwitch specification sheet
Hardware specifications provide detailed information for your IBM BNT RackSwitch, including
dimensions, electrical, power, temperature, environment, and service clearances.
Table 112. Dimensions
Height
44 mm (1.73 in.)
Table 113. Electrical
Electrical characteristics
Power requirements
Voltage
Frequency
Maximum thermal output
Phase
kVA
Table 114. Environmental and acoustical requirements
Environment/Acoustical
Airflow direction
Temperature, ambient operating
Temperature, (fan failure) operating
Temperature, storage
Relative humidity range
(non-condensing)
Maximum altitude
Heat dissipation
Acoustic noise
G8124ER RackSwitch specification sheet
Hardware specifications provide detailed information for your IBM BNT RackSwitch, including
dimensions, electrical, power, temperature, environment, and service clearances.
Table 115. Dimensions
Height
44 mm (1.73 in.)
84
Site and hardware planning
Width
439 mm (17.3 in.)
Operating
Rear-to-front
0°C - 40°C (32°F - 104°F)
0°C - 35°C (32°F - 95°F)
10% - 90% RH
3050 m (10000 ft)
444 Btu/hr
Less than 65 dB
Width
439 mm (17.3 in.)
Depth
445 mm (17.5 in.)
Properties
200 W
90 - 264 V ac
47 - 63 Hz
682.4 Btu/hr
1
0.204
Storage
-40ºC to +85ºC (-40°F to 185°F)
10% - 90% RH
12190 m (40000 ft)
Depth
381 mm (15.0 in.)
Weight (maximum)
8.3 kg (18.3 lb)
Weight (maximum)