IBM 8408-44E Site And Hardware Planning page 99

Hide thumbs Also See for 8408-44E:
Table of Contents

Advertisement

Table 110. Environment requirements (continued)
Environment
Shipping temperature
Shipping relative humidity
1. Nominal cubic feet per minute (CFM) is approximately 2030. Maximum CFM is approximately 4025.
2. Derate maximum allowable dry-bulb temperature 1°C (1.8°F) per 175 m (574 ft) above 950 m (3117 ft).
Table 111. Noise emissions
Declared A-weighted sound power level,
Product description
L
Model 7063-CR1
(1-socket) FC EKB0
Model 7063-CR1
(1-socket) at
maximum
temperature and
operation.
Model 7063-CR1
(1-socket) at
maximum
temperature with
acoustical doors
(front and rear), FC
EC08 and FC EC07,
installed.
Notes:
1. Declared level L
is the upper-limit A-weighted sound power level. Declared level L
Wad
A-weighted emission sound pressure level that is measured at the 1-meter bystander positions.
2. All measurements made in conformance with ISO 7779 and declared in conformance with ISO 9296.
3. 10 dB (decibel) equals 1 B (bel).
4. Under certain environments, configurations, system settings, and workloads, fan speeds are increased that result
in higher noise levels.
5. Notice: Government regulations (such as those prescribed by OSHA or European Community Directives) might
govern noise level exposure in the workplace and might apply to you and your server installation. This IBM
system is available with an optional acoustical door feature that can help reduce the noise that is emitted from
this system. The actual sound pressure levels in your installation depend upon various factors, including the
number of racks in the installation; the size, materials, and configuration of the room where you designate the
racks to be installed; the noise levels from other equipment; the room ambient temperature, and employees'
location in relation to the equipment. Further, compliance with such government regulations also depends upon
various extra factors, including the duration of employees' exposure and whether employees wear hearing
protection. IBM recommends that you consult with qualified experts in this field to determine whether you are
in compliance with the applicable regulations.
Electromagnetic compatibility compliance: CISPR 22:2008; CISPR 32:2012, CNS 13438 (Taiwan); EN
55032:2012 (EU, Australia); EN 55024:2010 (EU); EN 61000-3-2:2014 (EU, Japan); EN 61000-3-3:2013 (EU);
FCC, Title 47, Part 15 (USA); GB 9254-2008 (China); GB 17625.1-2012 (China); GB 17625.2-2007 (China);
30804.3.2-2013 (IEC 61000-3-2:2009) (EAEU);
30805.22-2013 (CISPR 22:2006) (EAEU);
(Canada); KN 32:2015 (Korea); KN 35:2015 (Korea); TCVN 7189:2009 (Vietnam); VCCI, April 2015 (Japan)
Recommended operating
requirements
1, 2, 3
(B)
Wad
Operating
5
7.8
4, 5
8.7
4, 5
7.9
CISPR 24-2013 (EAEU); ICES-003, Issue 6, January 2016
Allowable operating
requirements
Declared A-weighted sound pressure level,
L
(dB)
pAm
Idle
Operating
6.8
62
4, 5
8.7
69
4, 5
7.9
63
30804.3.3-2013 (IEC 61000-3-3:2008) (EAEU);
Nonoperating
requirements
-40°C to 60°C (-40°F to
140°F)
5% - 100%
Idle
50
69
63
is the mean
pAm
Site and hardware planning
83

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

8408-e8ePower systems series

Table of Contents