Hardware Management Console Physical Specifications - IBM Z10 Installation Manual

Business class
Hide thumbs Also See for Z10:
Table of Contents

Advertisement

Level 03c, May 2011

Hardware Management Console physical specifications

Note: This appendix will contain information for the Hardware Management
FC 0084/0090 - Hardware Management Console System Unit
Note: When planning the work area for the Hardware Management Console,
© Copyright IBM Corp. 2008, 2011
Console components applicable at the time of publication (determined by the
edition notice at the front of this document). Specifications for your Hardware
Management Console may differ from those presented below.
Height
Width
Depth
Weight minimum configuration as shipped
Weight maximum configuration
Low range input voltage
Input frequency range
High range input voltage
Input frequency range
Input kilovolt-amperes (kVA) (approximate)
Minimum configuration as shipped
Maximum configuration
Heat output in British thermal units (Btu) (approximate)
Minimum configuration
Maximum configuration
Server On - 0 to 914 m (2998 ft)
Server On - 914 m (2998 ft) to 2133.6 m
(7000 ft)
Server Off - to 2133 m (7000 ft)
Shipping
Humidity Range (operating and storage)
Note: Power consumption and heat output vary with the number and type of optional
features installed and the power-management optional features in use.
remember to allow a suitable space for a full-size keyboard and mouse.
Dimensions
438 mm (17.3 in.)
216 mm (8.5 in.)
540 mm (21.3 in.)
16.3 kg (36 lbs.)
25.2 kg (56 lbs.)
1
Input Power
Voltage switch setting 115 Vac
100 Vac - 127 Vac
47 - 53 Hz
Voltage switch setting 230 Vac
200 Vac - 240 Vac
57 - 63 Hz
0.20 kVA
0.55 kVA
1
Output Power
630 Btu/hr (185 watts)
1784 Btu/hr (523 watts)
Environmentals
10° to 35° C (50° to 95° F)
10° to 32° C (50° to 89.6° F)
10° to 43° C (50° to 109.4° F)
-40° to 60° C (-40° to 140° F)
8% - 80%
95

Advertisement

Table of Contents
loading

Table of Contents