Technical Data - Kemppi MinarcTig 180MLP Service Manual

Hide thumbs Also See for MinarcTig 180MLP:
Table of Contents

Advertisement

Technical data

Mains voltage
Rated power
Load capacity
Supply current, I1max
Supply current, I1eff
Connection cable / fuse
Fuse
Load capacity
Welding range
Open circuit voltage
Idle Power
Power ratio at max. current
Efficiency at max. current
Spark voltage
MMA welding electrodes
External dimensions(L x W x
H)
Weight
Degree of protection
Operating temperature range
Recommended generator
TIG
MMA
TIG
35 % ED
100 % ED
MMA
35 % ED
100 % ED
TIG
MMA
TIG
MMA
TIG
MMA
TIG
MMA
TIG
MMA
TIG / MMA
TIG / MMA
MMA
1 ~230 V ±15%, 50 / 60 Hz
Max. 6,7 kVA (180 A / 17,2 V)
Max. 7,0 kVA (140 A / 25,6 V)
180 A / 17,2 V
120 A / 14,8 V
140 A / 25,6 V
100 A / 24 V
29 A (180 A/17,2 V)
31 A (140 A/25,6 V)
18 A (120 A/14,8 V)
22 A (100 A/24,0 V)
3 x 2,5 mm² - 3 m Euro Schuko
16 A delayed
35 % ED 180 A/17,2 V
100 % ED 120 A/14,8 V
35 % ED 140 A/25,6 V
100 % ED 100 A/24 V
5 A/10,2 V-180 A/17,2 V
10 A/20,4 V-140 A/25,6 V
95 V
-
25 W
0,62 / 0,63
0,75 / 0,81
7-13 kV
Ø1,5-3,25 mm
(400 x 180 x 340) mm
7,8 kg (8,4 kg with supply cable)
IP 23 C
- 20 °C...+ 40 °C
> 7 kVA
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents