Setup functions
h = Minimum setting for pre-gas time
With this function you can set the pre-gas minimum time to the desired
value in the range 0 – 2 seconds.The factory setting is 0 seconds.
J = Minumum setting for post-gas time
With this function you can set the post-gas minimum time to the desired
value in the range 0 – 10 seconds.The factory setting is 1 second
L = Maximum setting for pre-gas time
With this function you can set the pre-gas maximum time to the desired
value in the range 5 – 20 seconds. The factory setting is 10 seconds.
o = Maximum setting for post-gas time
With this function you can set the post-gas maximum time to the desired
value in the range 15 – 99 seconds. The factory setting is 30 seconds.
S = Arc dynamics ( Arc Force )
When welding with MMA the power source automatically adjusts the dynamics.
With this function it is possible to adjust the dynamics manually.
Adjustment range is -3 - +5
-3 = ( softer arc )
+5 = ( harder arc )
t = Electrode ignition pulse
When welding with MMA the power source automatically adjusts the ignition pulse.
With this function it is possible to adjust the ignition pulse manually.
Adjustment range is -9 – 0
-9 = No ignition pulse
0 = Maximum ignition pulse