Setup functions
A = End current level selection
With this function you can set the welding current level when the arc will be extinguished.
0 = 15% of the welding current that is used.
1 = minimum current, which is 5 amperes in this power source.
B = Open-circuit selection
With this function you can change the open-circuit voltage.
0 = 95 volts
1 = 30 volts
C = Forced stop during downslope with a brief pressing on the switch
When downslope time is adjusted, the welding current drops normally to the
end current level and the arc is extinguished. This function allows to stop the arc during
the downslope with a quick press from the switch. Works only with 2T.
0 = Off
1 = On
d = Alternative switch logic
With this function it is possible to choose between four different switch logics.
0 = 4T-LOG
1 = Minilog
2 = 4T-LOG + Minilog
3 = Minilog + Search arc
E = Start current level selection (% of the welding current)
With this function you can set the current level when the arc ignites.
The value is a percentage of the welding current. The factory setting is 20%.
If the welding current is set to 100A, the start current level is 20A.
The adjustment range is 5–40%.
F = Restore factory settings
With this function you can reset the parameters to the factory settings.
0 = Do not restore factory settings
1 = Restore factory settings