Fuel Consumption - Miller Bobcat 250 Diesel Owner's Manual

Table of Contents

Advertisement

4-7. Fuel Consumption

2.00
1.75
1.50
1.25
1.00
0.75
0.50
0.25
IDLE
0.00
0
50
2.00
1.75
1.50
1.25
1.00
0.75
0.50
0.25
IDLE
0.00
0
1
OM-258413 Page 20
.
Complete Parts List is available at www.MillerWelds.com
100
150
200
DC WELD AMPERES AT 100% DUTY CYCLE
2
3
4
5
Aux Power KiloWatts at 100% DUTY CYCLE
250
300
350
6
7
8
9
A typical job using 1/8 in 7018
electrodes (125 amps, 20%
duty cycle), expect about 24
hours of operation per fuel fill.
Welding at 150 amps at 40%
duty cycle uses approximately
1/2 gallon per hour, or about 22
hours of operation per fuel fill.
400
10
260 051-A / 260 052-A