OUTPUT DATA AREA
The following table lists the registers of the output area (written by the master and acquired by the
instrument), common to all PROFINET, ETHERCAT, ETHERNET / IP fieldbuses.
The registers have a size of 16 bits. The registers written by the master in the output area are read by
the instrument at a maximum frequency of 90 Hz (60 Hz in the case of PROFIBUS fieldbus).
The size of the Output area set in the fieldbus master must coincide with the dimension set in the instrument.
Register
Byte
OUTPUT AREA REGISTER
address
1-2
0
Command Register
3-4
1
Data Register (MSW)
5-6
2
Data Register (LSW)
7-8
3
Monitor register
9-10
4
Active recipe
Active recipe correction factor
11-12
5
(MSW)
Active recipe correction factor
13-14
6
(LSW)
15-16
7
Batching cycles
Recipe/activity name
17-18
8
(character01 + character02)
Recipe/activity name
19-20
9
(character03 + character04)
Recipe/activity name
21-22
10
(character05 + character06)
Recipe/activity name
23-24
11
(character07 + character08)
Recipe/activity name
25-26
12
(character09 + character10)
Recipe/activity name
27-28
13
(character11 + character12)
Recipe/activity name
29-30
14
(character13 + character14)
31-32
15
Number of receipt steps
33-34
16
Recipe/activity steps
Recipe step, batching setpoint
35-36
17
(MSW)
Recipe step, batching setpoint
37-38
18
(LSW)
39-40
19
Type of activity
41-42
20
Fine (MSW)
43-44
21
Fine (LSW)
45-46
22
Inflight (MSW)
47-48
23
Inflight (LSW)
49-50
24
Tolerance (MSW)
51-52
25
Tolerance (LSW)
53-54
26
Waiting time
55-56
27
Product timeout
57-58
28
Fast output
Page 78
Notes
See the relevant table
Value INT. - Most significant word (See Table)
Value INT. - Less significant word (See Table)
Value corresponds to the equivalent register in the input area.
INT value for archive management from fieldbus
Value INT. - Most significant word
Value INT. - Less significant word
INT value for archive management from fieldbus
INT value for archive management from fieldbus
INT value for archive management from fieldbus
INT value for archive management from fieldbus
INT value for archive management from fieldbus
INT value for archive management from fieldbus
INT value for archive management from fieldbus
INT value for archive management from fieldbus
INT value for archive management from fieldbus
INT value for archive management from fieldbus
Value INT. - Most significant word for archive management from
fieldbus
Value INT. - Most significant word for archive management from
fieldbus
INT value for archive management from fieldbus
Value INT. - Most significant word for archive management from
fieldbus
Value INT. - Most significant word for archive management from
fieldbus
Value INT. - Most significant word for archive management from
fieldbus
Value INT. - Less significant word
Value INT. - Most significant word
Value INT. - Less significant word
INT value for archive management from fieldbus
INT value for archive management from fieldbus
INT value for archive management from fieldbus

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Pavone Systems MCT 1302

Table of Contents