Touch screen batching version with rs232 serial, analog and fieldbus
Table of Contents

Advertisement

PARAMETERS COM 2 WHEN PROFINET / ETHERCAT IS PRESENT
ENABLING FIELDBUS
Enabling the PROFINET / ETHERCAT; if OFF, no error message regarding the fieldbus communication
is displayed:
Selectable values:
OFF, ON
Default: OFF
INPUT AREA SIZE
Dimension of the input area for fieldbus (values expressed in bytes).
Selectable values:
32, 64, 96, 128
Default: 128
OUTPUT AREA SIZE
Dimension of the output area for fieldbus (values expressed in bytes).
Selectable values:
32, 64, 96, 128
Default: 128
In the case of an PROFINET fieldbus, the XML "GSDML-V2.3-HILSCHER-NIC 50-RE PNS 32-20160122.
xml" configuration file is provided. The size of the input and output areas set in the PLC (possible se-
lections: 32, 64, 96 or 128 bytes) must correspond to the size of the input and output areas selected in
the instrument ("INP.ADJ." And "OUT.ADJ." Parameters).
The instruments are supplied with the parameter "Profinet Name" not setup and with an IP address of
0.0.0.0.
In case of ETHERCAT fieldbus: the devices must be connected with a ring type (as specified by EtherCAT),
so refer to the installation manual for the use of INPUT and OUTPUT ports.
4 different XML setting files are provided:
"Hilscher NIC 50-RE ECS V2.2 32 Byte.xml" (input area 32 bytes, output area 32 bytes).
"Hilscher NIC 50-RE ECS V2.2 64 Byte.xml" (input area 64 bytes, output area 64 bytes).
"Hilscher NIC 50-RE ECS V2.2 96 Byte.xml" (input area 96 bytes, output area 96 bytes).
"Hilscher NIC 50-RE ECS V2.2 128 Byte.xml" (input area 128 bytes, output area 128 bytes).
The file that corresponds to the size of the input and output areas selected in the device must be imported
into the PLC (for example, if the device is set to ADJ. SET. = 128 and OUT.ADJ.=128, the file "Hilscher
NIC 50-RE ECS V2.2 128 Byte.xml" must be imported into the PLC). Multiple files with different sizes
can be imported, but, in this case, it will not be possible to perform the automatic search and setup of
devices on the network.