INSTALLATION
Connection to the gas supply
• This appliance is suitable for connection with rigid pipe or flexible hose. The isolating
manual shut-off valve connection point must be accessible when the appliance is installed.
• The flexible hose assembly must be certified to AS/NZS 1869 class B or D, be of
appropriate internal diameter for the total gas consumption (10mm), be kept as short as
possible (not exceeding 1200mm), must not be in contact with the floor or any hot surface
or sharp surface. The hose assembly must not be subject to strain, abrasion, kinking,
deformation or contact with any other appliance.
• Gas leakage and operation of the appliance must be tested by the installer before leaving.
Check burner flames are blue in colour, stable and completely ignite at both high and
low flame settings with no appreciable yellow tipping, carbon deposition, lifting, floating,
lighting back or objectionable odour. Test burners individually and in combination, When
satisfied with the operation of the cooker, please instruct the user on the correct method of
operation.
• Where the data plate is obscured by cabinetry when the cooker is in the installed position,
place the supplied duplicate data plate to a suitable adjacent surface or within the
instruction manual for future reference.
Gas connection
The gas intake connection of the appliance has a " male thread."
When making the connection, take care not to apply stresses of any kind
to the appliance.
Read these points before connecting to the gas supply;
• The gas connection point is a 1/2" BSP external thread located at the
rear of of the appliance (50mm from the edge).
• Ensure installation allows withdrawal of the appliance
• The appliance regulator provided must be orientated correctly
• The arrow showing the direction of the flow must be pointed correctly
• The regulator has a 1/2"BSP internal thread at inlet and outlet
Gas leakage and operation of the appliance must be tested by the
installer before leaving. Check burner flames are blue in colour, stable
and completely ignite at both high and low flame settings with no
appreciable yellow tipping, carbon deposition, lifting, floating, lighting
back or objectionable odour. Test burners individually and in combination,
When satisfied with the operation of the cooker, please instruct the user
on the correct method of operation.
27
A. Inlet pipe joint
B. Gasket
C. Stable union