Belling BFS54SCDF Instruction Manual page 25

Freestanding single door oven with gas cooktop
Table of Contents

Advertisement

INSTALLATION
Checking gas pressures
The cookers come in gas types: Natural gas and Universal LPG: If the cooker is required to
use LPG, a conversion kit is included. Before installation check that the cooker is suitable
for the gas supply. To do this check the gas type on the carton sticker or on the data plate
behind the bottom of the oven door.
The following shows the supply and operating pressures for various gas supplies.
Operate pressure at appliance test point: 1.00 KPa (Natural gas); 2.75 KPa (Universal LPG) as
the following table shows the injector sizes for each burner.
Gas Type: Natural Gas @ 1.00kPa Test Point Pressure
Burner
Wok
Semi-rapid
Auxiliary
ULPG @ 2.75kPa Test Point Pressure
Burner
Wok
Semi-rapid
Auxiliary
Total Gas Consumption:
Model
Hob Model
Injector Size (mm)
1.70mm
1.18mm
0.90mm
Injector Size (mm)
1.10mm
0.72mm
0.57mm
Natural Gas (MJ/h)
31.0
25
N.G.C. (MJ/h)
14.0
6.5
4.0
N.G.C. (MJ/h)
15.5
7.5
4.0
ULPG (MJ/h)
34.5

Hide quick links: