8
Run drain line:
a:
Run a drain line to a
discharge point, checking for
any obstructions or possible
kinks.
FOLLOW REGIONAL WATER
REGULATIONS.
b:
Before connecting the drain line
to the unit, slide on the stainless
steel jubilee clip.
c:
Push the drain line onto the
barbed fitting and tighten the
jubilee clip securely.
Please note:
Drain lines must not run more than
2.4m up or exceed a total of 9m. The
drain line must not be restricted or
kinked.
Kinetico Premier Compact Water Softener Installation Instructions
Review
1
Pressure:
Where a pressure regulating valve
has been fitted, ensure it has been
correctly set to 6 bar.
2
Drain line:
Ensure the drain line is securely
attached, has no restrictions or kinks,
uses an airgap and is fully compliant.
3
Overflow:
Ensure the overflow has no kinks, is
securely attached and that water is
able to fall away with gravity.
4
Inlet/Outlet Connections
Ensure the hoses/plumbing are
attached securely, using the
screened washers provided, and
are firmly held in place using the
retaining bracket and pin.
5
By-pass assembly:
Ensure the inlet and outlet valves
are closed and that the by-pass
valve is open.