10

Installation review and startup

1
Test pressure:
Test incoming pressure to the unit and adjust pressure reducing valve if the pressure
is above 6 bar.
2
Secure drain line:
Make sure the drain line is secure, using an airgap that is compliant.
Main inlet valve:
3
With the by-pass in position (inlet closed, outlet closed, by-pass open), open the
main inlet valve slowly and check for leaks in the plumbing.
Finish system set up:
4
If cabinet does not fill up with water, add 4 litres of water to the Essential cabinet.
Add a quality grade of tablet salt.
IMPORTANT:
On no account should granular salt be used in any Kinetico Water Softener.
Start a manual regeneration:
5
Using a #2 Phillips screwdriver, push down firmly on the actuator and slowly turn
clockwise, listening for four clicks to start the regeneration. At this point you should
hear water begin to run through the system. If you do not hear water running
through the system, the disc may not have been advanced far enough, continue to
turn.
After 15 minutes the regeneration will be complete and the softener is ready for
service.
6
Check for Leaks:
On completion, check for leaks and test the water at a softened water tap. Explain
the system to the customer including operation of the by-pass and how to load salt.