Download Print this page

Installation Review; Start-Up Instructions - Kinetico 2020C Installation Instructions Manual

Hide thumbs Also See for 2020C:

Advertisement

2020c water softener
Installation Instructions

InstaLLatIon reVIew

1
test Pressure
Test incoming pressure and fit a pressure limiting valve if the pressure is near
maximum. Min./Max. Operating Pressure is 15psi/125psi.
2
Main Inlet Valve
With the by-pass in the by-pass position, turn on the main inlet valve slowly and check
for leaks in the plumbing.
3
secure Drain Line
Make sure the drain line is secure and using an airgap.
4
Pressurising
Open the inlet valve and allow the softeners to pressurize. Water may run to drain
until the unit is fully pressurised.
5
Brine Drum
With the unit in service and under pressure, allow the brine drum to fill with water
until the brine valve shuts off. The water level should be approximately one inch over
the grid plate.
tip: If the cabinet does not fill with water, simply lift the brine valve from the brine well
and gently push down on the float rod until water starts to flow from the valve. Return the
valve to the brine well.
06
visit www.kinetico.co.uk
startUP InstrUCtIons
1
IMPortant:
Using a Phillips head screwdriver, manually cycle the softener to the backwash
position by turning the black dot on the white control disc to the letter "w"in the word
"backwash"on the clear cap. You will hear a rush of water and air going to the drain.
When the vessel has finished its cycle, repeat the procedure on the next tank and
allow it to finish its cycle. See Figure 4.
2
trapped air
After the unit is pressurized, open the outlet valve, ensure isolation valve is closed.
Open a tap in the house to release trapped air from the lines.
note: When the installation is complete, plumbing lines must be chlorintated for
sanitisation. Common household bleach may be used. The amount of bleach needed can
vary depending on plumbing size, length and fixtures.
1
Lid removal
If you have installed the softener in a confined area that will not permit the hinged
lid to be opened, remove the lid and hinges from the cabinet. Insert the alternate
connectors provided into the slots on the cabinet previously occupied by the hinges.
Place the lid on the cabinet. See Figure 5. The alternate connectors will permit easy
removal of the lid for access to the salt bay.
figure 4
Indicator Dot
Softener Valve Screw
freephone 0800 0151 380
2020c water softener
Installation Instructions
07

Hide quick links:

Advertisement

loading