16

Useful information

1
Should water be present in the salt compartment?
Yes, it is normal to see water at a level of 25mm above the salt grid
(see page 13). If water is not present to this level:
a:
Fill softener with water until the level is 25mm over the salt grid, then
conduct a manual regeneration.
b:
To manually regenerate using a Phillips head screwdriver push down on
the actuator, and slowly turn CLOCKWISE ONLY until the actuator tab has
advanced the indicator dot to the word "BRINE".
c:
You will hear a rush of water and air going to the drain.
d:
When the vessel has finished its cycle (approx 12 mins), repeat the procedure,
advance the indicator dot to the word "BRINE" in the next cycle and allow to
finish (approx 12 mins).
Indicator
Kinetico Premier Compact Water Softener Installation Instructions
Actuator

Advertisement