Modine Manufacturing Sentinel UVV Installation And Service Manual

Modine Manufacturing Sentinel UVV Installation And Service Manual

Unit ventilator

Advertisement

Quick Links

WARNING
Improper installation, adjustment, alteration,
service or maintenance can cause property
damage, injury or death, and could cause
exposure to substances which have been
determined by various state agencies to cause
cancer, birth defects or other reproductive harm.
Read the installation, operating and maintenance
instructions thoroughly before installing or
servicing this equipment.
PLEASE BE SURE TO LEAVE IT WITH THE OWNER WHEN YOU LEAVE THE JOB.
INSTALLATION AND SERVICE MANUAL
THIS MANUAL IS THE PROPERTY OF THE OWNER.
Models UVV and UVD
IMPORTANT
 T heuseofthismanualisspecificallyintended
foraqualifiedinstallationandserviceagency.
Aqualifiedinstallationandserviceagencymust
perform all installation and service of these
appliances.

Inspection On Arrival

1. Inspect unit upon arrival. In case of damage, report
immediately to transportation company and your local factory
sales representative.
2. Check serial plate on unit to verify that the power supply
meets available electric power at the point of installation.
3. Inspect unit upon arrival for conformance with description of
productordered(includingspecificationswhereapplicable).
AIR 3-500.3
5H1015460000
April, 2019
Sentinel
®
Unit Ventilator

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Sentinel UVV and is the answer not in the manual?

Questions and answers

Summary of Contents for Modine Manufacturing Sentinel UVV

  • Page 1: General Information

    AIR 3-500.3 5H1015460000 April, 2019 INSTALLATION AND SERVICE MANUAL Sentinel ® Unit Ventilator Models UVV and UVD IMPORTANT  T heuseofthismanualisspecificallyintended foraqualifiedinstallationandserviceagency. Aqualifiedinstallationandserviceagencymust perform all installation and service of these appliances. Inspection On Arrival 1. Inspect unit upon arrival. In case of damage, report immediately to transportation company and your local factory sales representative.
  • Page 2: Table Of Contents

    Performance Data ........12 Modine Manufacturing Company. Refer to the rating plate...
  • Page 3: Si(Metric)ConversionFactors

    UNIT LOCATION / INSTALLATION Table 3.1 - SI (Metric) Conversion Factors Electrical Electrical wiring should be done in accordance with all To Convert Multiply By To Obtain To Convert Multiply By To Obtain applicable national and local codes. It is the responsibility of the "W.C.
  • Page 4: Wiring/Terminal Strip Connections

    INSTALLATION Installation of wiring must conform with local building codes, Figure 4.1 - Do Not Drill Zone - UVD Only or in the absence of local codes, with the National Electric Code ANSI/NFPA 70 - Latest Edition. Unit must be electrically grounded in conformance to this code.
  • Page 5: Start-Up Procedure

    START-UP PROCEDURE START-UP PROCEDURE Hot Water/Steam Heat: When the temperature decreases below the heating setpoint, the heating valve will modulate open and fan will be energized. IMPORTANT Electric Heat: When the temperature decreases below the Start-up and adjustment procedures should be performed by heatingsetpoint,thefirststageofelectricheatwillbeenergized. aqualifiedserviceagency.
  • Page 6: Start-Up Sheet - Examples

    START-UP SHEET - EXAMPLE Figure 6.1 - Start-Up Sheet - EXAMPLE Page 1 AIR 3-500.3...
  • Page 7 START-UP SHEET - EXAMPLE Figure 7.1 - Start-Up Sheet - EXAMPLE Page 2 AIR 3-500.3...
  • Page 8: Unit Dimensions

    DIMENSIONS Figure 8.1 - Dimensions – Base Unit UVV (Digit 9: Ventilation Configuration = A, B or C) NOTE: 1.BaseUnitUVV(Digit9:VentilationConfiguration=A)willbeprovidedwithnoExhaustAirOutlet. 2. Unit will be provided with top and bottom piping knockouts. Reference Digit 20 in unit nomenclature to understand where terminations are located. AIR 3-500.3...
  • Page 9 Figure 9.1 - Dimensions – Base Unit UVV (Digit 9: Ventilation Configuration = D) NOTE: Unit will be provided with top and bottom piping knockouts. Reference Digit 20 in unit nomenclature to understand where terminations are located. AIR 3-500.3...
  • Page 10 DIMENSIONS Figure 9.1 – Dimensions – Base Unit UVV (Digit 9: Ventilation Configuration = E) NOTE: Unit will be provided with top and bottom piping knockouts. Reference Digit 20 in unit nomenclature to understand where terminations are located. AIR 3-500.3...
  • Page 11 DIMENSIONS Figure 11.1 – Dimensions – Base Unit UVD (Digit 9: Ventilation Configuration A, B or C) NOTE: 1.BaseUnitUVD(Digit9:VentilationConfiguration=A)willbeprovidedwithnoExhaustAirOutlet. 2. Unit will be provided with top and bottom piping knockouts. Reference Digit 20 in unit nomenclature to understand where terminations are located. AIR 3-500.3...
  • Page 12: Performance Data

    PERFORMANCE DATA Table 12.1 - Technical Data Units Coils - ‘A’ Frame - Chilled Water and Hot Water Quantity Face Area FT² 4.36 4.36 4.36 4.36 Coils - Slab - Hot Water and Steam Quantity Face Area FT² 3.33 3.33 3.33 3.33 SUPPLY FAN...
  • Page 13: Accessory Installation

    ACCESSORY INSTALLATION ACCESSORY INSTALLATION 3. Use the masonry screws provided to fasten the wall sleeve flangetothewall.Donotattachthewallsleevetothe IMPORTANT classroom unit. 4. S lidethelouver(soldseparately)intotheinnerwallsleeve. Useself-tappingscrews(byothers)tosecurethelouverto Theuseofthismanualisspecificallyintendedfora the wall sleeve. See Figure 13.2. qualifiedinstallationandserviceagency.Aqualified Figure 13.2 - Louver and Inner Wall Sleeve installation and service agency must perform all installation and service of these appliances.
  • Page 14 ACCESSORY INSTALLATION Figure 14.2 - Splitter Plate Insulation 9. C leanthefrontflangeoftheoutersplitterplateandattachthe gaskettotheflange.SeeFigure14.1. Figure 14.1 - Splitter Plate Installation 1" FOIL FACED INSULATION ANGLE SPLITTER PLATE (BYOTHERS) SLIGHTLY DOWNWARD TOWARD THE OUTSIDE OF THE BUILDING GASKET CLEAN TOP SURFACE OF SPLITTER PLACE BEFORE INSTALLING INSULATION OUTER SPLITTER...
  • Page 15: Rear Extension

    ACCESSORY INSTALLATION REAR EXTENSION (Optional) PLENUM (Optional) Instructions only applicable to accessories sold by Modine. If not Instructions only applicable to accessories sold by Modine. If not provided by Modine, consult manufacturer’s recommendations. provided by Modine, consult manufacturer’s recommendations. The rear extension is designed to provide a sealed transition Thefieldinstalledplenumisdesignedtodischargeairdirectly from the fresh air intake and exhaust air outlet on the back of into the space without ductwork to distribute air.
  • Page 16: Duct Shroud,Filler Panel And Floorstand

    ACCESSORY INSTALLATION DUCT SHROUD (Optional) FILLER PANEL (Optional) Instructions only applicable to accessories sold by Modine. If not Instructions only applicable to accessories sold by Modine. If not provided by Modine, consult manufacturer’s recommendations. provided by Modine, consult manufacturer’s recommendations. Thefieldinstalledfillerpanelisdesignedtobeinstalledabove Thefieldinstalledductshroudisdesignedtocoverductwork a rear extension, and behind a plenum or duct shroud so the...
  • Page 17: Maintenance

    When servicing or repairing this equipment, use only factory- withoutfilters. approved service replacement parts. A complete replacement parts list may be obtained by contacting Modine Manufacturing Every SIX (6) MONTHS Company. Refer to the rating plate on the appliance for...
  • Page 18: Replacement Parts

    MAINTENANCE REPLACEMENT PARTS Figure 18.2 - Serial Plate EXAMPLE Foreaseofidentificationwhenorderingreplacementpartsor contacting the factory about your unit, please quote the unit type and unit serial number. This information can be found on the serialplateattachedtoyourunit(seeFigure18.2). When a component part fails, a replacement part should be obtained through our Parts Department.
  • Page 19: Troubleshooting

    TROUBLESHOOTING Figure 19.1 - Troubleshooting - General Trouble Possible Cause Possible Remedy UV A. Unit Not Operating - 1. Unit mounted disconnect in the “OFF” position. 1. Turn the disconnect switch to the “ON” position. Power On 2. Unit mounted 3-speed selector switch in the “0” 2.
  • Page 20: Warranty

    Burners High Intensity Infrared Units Sheet Metal Parts All Products As Modine Manufacturing Company has a continuous product improvement program, it reserves the right to change design and specifications without notice. Commercial Products Group Modine Manufacturing Company 1500 DeKoven Avenue Racine, WI 53403 Phone:1.866.823.1631(tollfree)

This manual is also suitable for:

Sentinel seriesSentinel uvd

Table of Contents