11-2 Horizontal 
When the vibration gauge is installed in the horizontal direction, it should be placed on
the level of the rotation axis, does not put too high, so as not to increase the vibration
value. Put the higher position, the greater the value of the horizontal vibration. At this
time, the Z axis of the vibration gauge is the horizontal direction. If you measure only
one point, it is recommended to use this point. Vibration measurement of the vertical direction,
to be placed on top of the rotating shaft, then the vibration of the Z-axis is the vertical
direction, please note that the two legs of the magnet parallel to the axis of rotation, it can
be fixed in the motor arc on. 
 
 
 