TECOM AG-300 Plus2 Operation Manual

Smart portable vibration diagnosis instrument

Advertisement

Quick Links

AG-300 Plus2
Gateway
Operation Manual
Copyright © 2017, All Rights Reserved.
Ver: R01 D/C: 106-1121

Advertisement

Table of Contents
loading

Summary of Contents for TECOM AG-300 Plus2

  • Page 1 AG-300 Plus2 Gateway Operation Manual Copyright © 2017, All Rights Reserved. Ver: R01 D/C: 106-1121...
  • Page 2 Federal Communications Commission (FCC) Statement Statement shall be listed in the label (if the product is smaller than palm size, it could be listed in user manual for instead.) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference and 2) this device must accept any interference received, including interference that may cause undesired operation of the device.
  • Page 3: Table Of Contents

    Tecom AG-300 Plus2 IoT Gateway Operation Manual Table of contents Overview ............................3 AG-300 Plus2 Configuration ......................5 1. System structure ......................5 2. Equipment wiring ......................5 3. RS485 wiring ........................7 4. Power bank wiring......................8 5. Equipment dimension ....................8 6.
  • Page 4: Overview

    Tecom AG-300 Plus2 IoT Gateway Operation Manual Overview Tecom smart portable vibration diagnosis instrument is one of the most innovative mobile maintenance products in the world. By making the most of IoT, sensor, and management software technology it is designed to measure vibration of running E&M equipment without extra power cord or network cable.
  • Page 5 Tecom AG-300 Plus2 IoT Gateway Operation Manual In situ and instant vibration diagnosis information Productivity 4.0...
  • Page 6: Ag-300 Plus2 Configuration

    A. Connect AG-300 Plus2 to VB-200STU with RS485(1/2) B. Connect AG-300 Plus2 DC Jack to power bank to the power cord C. WiFi connect smartphone to built-in WiFi router of AG-300 Plus2 D. Mount (magnetic) vibration gauge to target equipment according to its installation...
  • Page 7 APP; follow the following diagram and steps E~F for computer and the Internet connection as required. E. Connect AG-300 Plus2 WAN port (blue) and LAN port of ADSL modem with network cable F. Connect AG-300 Plus2 LAN port (yellow) and PC with network cable (for system...
  • Page 8: Rs485 Wiring

    A D S L m o d e m RS485 wiring (1) AG-300 Plus2 E-gateway AG-300 Plus2 supports up to 4 vibration gauge with RS485 (USB) connection as shown in figure below: RS485 (USB) set 1 RS485 (USB) set 2...
  • Page 9: Power Bank Wiring

    Power bank wiring This portable vibration diagnosis instrument comes with power bank power cord, please connect DC Plug to DC jack of AG-300 Plus2 and USB connector to USB port in power bank as shown in figure below: e-gateway AG-300 Plus2...
  • Page 10: Ag-300 Plus2 View

    Tecom AG-300 Plus2 IoT Gateway Operation Manual AG-300 Plus2 view...
  • Page 11: Equipment Setup

    Equipment setup Network setup Step 1 - Keep your PC / NB and e-gateway AG-300 Plus2 in the same LAN segment (better have DHCP enabled on your PC / NB) - Connect PC/NB and AG-300 Plus2 (LAN port) with Ethernet cable...
  • Page 12 Tecom AG-300 Plus2 IoT Gateway Operation Manual Step 2 (Skip this step for DHCP PnP network) - In main menu on the left, click [Settings] [WAN]. - In WAN connection type dropdown menu, select [STATIC (Fixed IP)] - IP address: input IP data.
  • Page 13: Account Setup

    Tecom AG-300 Plus2 IoT Gateway Operation Manual Account setup Step 1 In main menu on the left, click [Settings] [Unit pairing] before selecting [Add] button. Step 2 Check the [Select] column before selecting the [Edit] button...
  • Page 14 Tecom AG-300 Plus2 IoT Gateway Operation Manual - Name : input user name. : e . g . 1 0 3 ( y o u c a n h a v e 2 0 a c c o u n t w i t h n u m b e r i n r a n g e o f 1 0 0 - 1 1 9 ) .
  • Page 15: Vb200 Setup

    Tecom AG-300 Plus2 IoT Gateway Operation Manual - To edit user account: check the [Select] column; click the [Edit] button, and the existing settings of the account displays for you to change. - To delete user account: when the user was disconnected check the [Select] column, click the [Delete] button to remove the account.
  • Page 16 Tecom AG-300 Plus2 IoT Gateway Operation Manual - Name: "VB-200" or any name you like. - Line: select line 3 ~ 4 (line 1~2 added by factory default). - RS485 ID: please fill in a value compliant with your RS485 configuration (this system support RS485 ID in range of 0-15).
  • Page 17 Tecom AG-300 Plus2 IoT Gateway Operation Manual - To edit the settings of VB-200: check the [Select] column, click the [Edit] button, and the existing settings display for you to change. - To delete settings of VB-200: check the [Select] column, click the [Delete] button to remove the VB-200 vibration gauge.
  • Page 18: Wireless Setup

    Tecom AG-300 Plus2 IoT Gateway Operation Manual Wireless setup Designed for e-gateway AG-300 Plus2 hardware, the "wireless setup" page contains options of WiFi mode, "Basic", "Advanced", "Security", and "Station list". You may set WiFi mode into "Wireless AP mode" and "Wireless client mode".
  • Page 19 Tecom AG-300 Plus2 IoT Gateway Operation Manual 4.1.1 Basic wireless settings This option enables user to set up basic wireless communication parameters including network name and mode with WiFi function default to Enable. WiFi [Enable] page: see figure below: WiFi [Disable] page: see figure below:...
  • Page 20 Tecom AG-300 Plus2 IoT Gateway Operation Manual 4.1.2 Advanced wireless settings This option is aimed at setting up country/region and support channel with page as shown in figure below: 4.1.3 Wireless security/encryption settings This option is aimed at setting up wireless security and encryption to prevent equipment access and monitoring without certification;...
  • Page 21 Tecom AG-300 Plus2 IoT Gateway Operation Manual Set up WPA algorithm, pass phrase, and key renewal interval; once set up and saved successfully users are required to input pass phrase set up here to connect to WiFi.
  • Page 22 Tecom AG-300 Plus2 IoT Gateway Operation Manual The client end is required to log in WiFi router of e-gateway AG-300 Plus2 with his/her smartphone:...
  • Page 23: 4.2 Wifi Mode Setting

    Tecom AG-300 Plus2 IoT Gateway Operation Manual 4.1.4 Station list Users of this solution may monitor clients connected to AP. 4.2 WiFi mode setting Select STA mode and click [Apply] in the WiFi mode setting.
  • Page 24 Tecom AG-300 Plus2 IoT Gateway Operation Manual 4.2.1 Station profile Having a gateway as an ordinary client, this page displays information of APs saved in the gateway; you may add, delete, and edit information of desired AP; select an AP and click "Open", the gateway will then auto connect to the AP; even after gateway restart connection to pre-set AP will be established automatically.
  • Page 25 Tecom AG-300 Plus2 IoT Gateway Operation Manual 4.2.2 Edit station profile In most cases, users may change parameters of "Name", "SSID", "BSSID" and "Security policy" and leave default value of the others intact in the station profile edit page. "Name": name of the profile "SSID": name of AP...
  • Page 26 Tecom AG-300 Plus2 IoT Gateway Operation Manual 4.2.3 Station link status Link information after gateway connected to AP is shown here. 4.2.4 Scan near AP...
  • Page 27: Hardware Setup

    Tecom AG-300 Plus2 IoT Gateway Operation Manual Scan gateway neighboring APs for information Click "Connect" to connect the AP; data of the latter are not saved (data lost after gateway restarted). Click "Rescan to scan" neighboring APs once again. Scanning may fail to identify all APs when there are many available nearby;...
  • Page 28: App Software Operation

    - Account: 100 (there are 20 accounts available with ID in range of 100-119). - Password: your personal password (better the same as account ID). - Server IP: the IP address or server ID set by AG-300 Plus2. - Server name: name of AG-300 Plus2 server.
  • Page 29 (1) Is networking function of your smartphone enabled? (2) Is network signal of smartphone in good conditions? (3) Is AG-300 Plus2 powered on? (4) AG-300 Plus2 equipment pairing set up? (5) Is AG-300 Plus2 networking function in normal conditions? (6) Is smartphone and AG-300 Plus2 WiFi [connected]?
  • Page 30 Tecom AG-300 Plus2 IoT Gateway Operation Manual Note: you may get Host ID on the AG-300 setup page once it is connected to external network. In the main menu on the left, click [Device Info] [Status Overview] option, to get Host ID in the System Info window.

Table of Contents