HUAWEI MC509 CDMA Mini PCIe Module
Hardware Guide
RF cable for testing

4.3.2 Test Standards

Huawei modules meet all 3GPP2 test standards. Each module passes strict tests at
the factory and thus the quality of the modules is guaranteed.

4.4 Conducted Rx Sensitivity and Tx Power

4.4.1 Conducted Receive Sensitivity

The conducted receive sensitivity is a key parameter that indicates the receiver
performance of MC509 Mini PCIe module. The conducted receive sensitivity refers to
the weakest signal that the module at the antenna port can receive.
Table 4-2 lists the typical tested values of the MC509 Mini PCIe module.
Table 4-2 MC509 Mini PCIe module conducted Rx sensitivity
Band
CDMA 800 Primary
CDMA 1900 Primary
Table 4-3 MC509 Mini PCIe module GPS main characteristics
Item
Receive Sensitivity (Cold start)
Receive Sensitivity (Hot start)
Receive Sensitivity (Tracking mode)
Issue 03 (2014-12-26)
L08-C014-350 of DRAKA COMTEQ or Rosenberger
Cable length: 29 cm
The compensation for different frequency bands relates to the cable and the test
environment.
The instrument compensation needs to be set according to the actual cable conditions.
Typical value (Unit: dBm)
–107.5
–109
–107
–109
The typical values are the average of some test samples.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Note
1 x (FER < 0.5%)
EVDO (PER < 0.5%)
1 x (FER < 0.5%)
EVDO (PER < 0.5%)
Typical Value (Unit: dBm)
–145
–157.5
–158
RF Specifications
28