4.3.2 Test Standards

Huawei modules meet all 3GPP test standards. Each module passes strict tests at the
factory and thus the quality of the modules is guaranteed.

4.4 Conducted Rx Sensitivity and Tx Power

4.4.1 Conducted Receive Sensitivity

The conducted receive sensitivity is a key parameter that indicates the receiver
performance of MU509-65.
Table 4-2 MU509-65 conducted Rx sensitivity
Band
WCDMA Band 2
WCDMA Band 5

4.4.2 Conducted Transmit Power

The conducted transmit power is another indicator that measures the performance of
MU509-65. The conducted transmit power refers to the maximum power that the
module tested at the antenna port can transmit. According to the 3GPP protocol, the
required transmit power varies with the power class.
Table 4-3 MU509-65 conducted Tx power
Band
WCDMA Band 2
WCDMA Band 5
Issue 01 (2016-04-08)
Compensation for 2100 MHz, 1900MHz or 1800 MHz: 0.8 dB
The compensation for different frequency bands relates to the cable and the test
environment.
The instrument compensation needs to be set according to the actual cable conditions.
The test values are the average of some test samples.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Typical Value
Note
(Unit: dBm)
–111
BER < 0.1%
–110.5
BER < 0.1%
Typical Value
23.5
23.5
RF Specifications
Note
± 1 dB
± 1 dB