Conducted Rf Measurement; Test Environment; Test Standards; Conducted Rx Sensitivity And Tx Power - Huawei MU509 Series Hardware Manual

Hsdpa lga module
Hide thumbs Also See for MU509 Series:
Table of Contents

Advertisement

HUAWEI MU509 Series HSDPA LGA Module
Hardware Guide
Operating Band
GSM 850
GSM 900
GSM 1800 (DCS)
GSM 1900 (PCS)

4.4 Conducted RF Measurement

4.4.1 Test Environment

Test instrument
Power supply
RF cable for
testing

4.4.2 Test Standards

Huawei modules meet all 3GPP test standards relating to both 2G and 3G. Each
module passes strict tests at the factory and thus the quality of the modules is
guaranteed.

4.5 Conducted Rx Sensitivity and Tx Power

4.5.1 Conducted Receive Sensitivity

The conducted receive sensitivity is a key parameter that indicates the receiver
performance of MU509.
The 3GPP Protocol Claim column in Table 4-2 lists the required minimum values,
and the Test Value column lists the tested values of MU509.
Issue 09 (2014-03-06)
R&S CMU200
KEITHLEY 2306
L08-C014-350 of DRAKA COMTEQ or Rosenberger
Cable length: 29 cm
Compensation for 850 MHz or 900 MHz: 0.6 dB
Compensation for 2100 MHz, 1900MHz or 1800 MHz: 0.8 dB
The compensation for different frequency bands relates to the cable and the test
environment.
The instrument compensation needs to be set according to the actual cable conditions.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Tx
824 MHz–849 MHz
880 MHz–915 MHz
1710 MHz–1785 MHz
1850 MHz–1910 MHz
RF Specifications
Rx
869 MHz–894 MHz
925 MHz–960 MHz
1805 MHz–1880 MHz
1930 MHz–1990 MHz