Table 2-16
Component
Chassis
Accessories
Rack-mount kit
Cable management kit
Power cable
EIP port jackscrews
FEIP port jackscrews
FSIP interface cables
Optional interface cables
Other optional equipment
Documentation
System components:
RP
SP
SSP
RSP7000
RSP7000CI
AIPs
CIPs
EIPs
Component List
Description
Router chassis
The following accessories may arrive in separate shipping containers:
Two chassis ears, four M4 x 10-mm Phillips flathead screws, and eight 10-32 x 3/8" slotted screws
Two brackets and six M3 x 6-mm Phillips screws for attaching the brackets to the chassis
One power cable
One jackscrew conversion kit for each Ethernet port
One jackscrew conversion kit for each Fast Ethernet port
Verify that you receive 1 of the following adapter cables for each FSIP port:
EIA/TIA-232 DTE or DCE serial port adapter cable, 1 per port required
EIA/TIA-449 DTE or DCE serial port adapter cable, 1 per port required
V.35 DTE or DCE serial port adapter cable, 1 per port required
X.21 DTE or DCE serial port adapter cable, 1 per port required
EIA-530 DTE serial port adapter cable, 1 per port required
One pair of M-30 metric thumbscrews with each cable type except V.35
AUI or Ethernet transceiver cable, 1 per EIP port required
One jackscrew conversion kit for each Ethernet AUI ports (install only if needed)
Token Ring interface cable, 1 per TRIP port required
FDDI interface cables, 1 or 2 multimode, 2 or 4 single-mode for each FIP
HSSI interface cable, 1 per port required
Null modem cable for back-to-back HSSI connections
MIP cables, 1 per port required
AIP cables and types, 1 per AIP port required
Ethernet transceiver or 802.3 attachment unit
Fast Ethernet transceiver or 802.3 attachment unit
Flash memory card
MAU, CSU/DSU for network connections
Cisco 7000 User Guide and UniverCD (ship with chassis), and any printed documentation as
ordered
Processor slots 5 and 6 should contain an SP (or SSP) and RP, or an RSP7000 (slot 5) and an
RSP7000CI (slot 6), and any combination of 5 interface processors or blank interface processor
fillers
Installed in the RP slot (top slot)
Installed in SP slot instead of SSP (immediately below the RP)
Installed in SSP slot instead of SP (immediately below the RP)
Installs in the SP (or SSP) slot (slot 3) instead of the SP (or SSP). Used with the RSP7000CI.
Installs in the RP slot (slot 4) instead of the RP. Used with the RSP7000.
Enter slot locations and port addresses on Configuration Worksheet
Enter slot locations and port addresses on Configuration Worksheet
Enter slot locations and port addresses on Configuration Worksheet
Initial Configuration Information
Rec'd