Site Requirements
Network connections to the coaxial cables are tapped into a network segment and must be spaced at
specific intervals. Table 2-1 lists the maximum number of connections (taps) per segment and the
intervals at which they must be placed. A maximum of four repeaters can be used to link segments
in a single network.
Table 2-1
Parameter
Cable diameter
Max. segment length
Max. connections (taps) per segment
Min. connection (tap) spacing
The unshielded twisted-pair (UTP) cabling used with 10BaseT is suitable for voice transmission, but
may incur problems at 10-Mbps transmission rates. UTP wiring does not require the fixed spacing
between connections that is necessary with the coaxial-type connections. IEEE recommends a
maximum distance of 328 feet (100 meters) between station (connection) and hub for 10BaseT
connections.
Fast Ethernet Connections
IEEE 802.3u specifies several different physical layers for 100BaseT: among them are 100BaseTX,
which is 100BaseT, half duplex, over Category 5, unshielded twisted-pair (UTP), Electronics
Industry Association/Telecommunications Industry Association (EIA/TIA)–568-compliant cable;
100BaseFX, which is 100BaseT, full duplex or half duplex over optical fiber; and 100BaseT4, which
is 100BaseT using Category 3, 4, or 5 UTP or shielded twisted- pair (STP) cabling with four pairs.
100BaseT4 is also called 4T+ or T2, which is 2-pair UTP over Category 3 cable.
Table 2-2 lists the cabling specifications for 100-Mbps transmission over 100BaseT, Category 5
UTP and MII connections.
Table 2-2
Parameter
Cable specification
Maximum cable length
Maximum segment length
Maximum network length
1. EIA/TIA-568 or EIA/TIA-568 TSB-36 compliant.
2. Cisco Systems does not supply Category 5 UTP RJ-45 or 150-ohm STP MII cables. Both are commercially available.
3. AWG = American Wire Gauge. This gauge is specified by the EIA/TIA-568 standard.
4. This is the cable between the MII port on the FEIP port adapter and the appropriate transceiver.
5. This refers specifically to any two stations on a repeated segment.
Table 2-3 summarizes the characteristics of 100BaseT with respect to IEEE 802.3u physical
characteristics.
2-6 Cisco 7010 Hardware Installation and Maintenance
Ethernet Coaxial Connection Limits for 10-Mbps Transmission
Connection Limits for 100-Mbps Transmission
RJ-45
1
2
Category 5
UTP
, 22 to 24 AWG
100 m (328 ft.) for 100BaseTX
5.
200 m (656 ft.)
(with 1 repeater)
10Base5
0.4" (1 cm)
1640' (500 m)
100
8.2' (2.5 m)
MII
3
Category 3, 4 or 5, 150-ohm UTP or STP or multimode optical fiber
0.5 m (1.64 ft.) (MII-to-MII cable
5
1 m (3.28 ft.)
or 400 m (1,312 ft.) for 100BaseFX
10Base2
0.25" (0.6 cm)
656' (200 m)
30
1.64' (0.5 m)
4
)