CONTROL SYSTEM
Terminal assignment
Each of the E-ECU terminals listed in Table 2-14 is assigned multiple functions. The active function for each
terminal can be changed by mapping.
By default, function 1 is enabled. Contact Yanmar for setting change.
Terminal
Terminal
No.
name
E24
APP-IP1 Droop selection Starter enable
E14
APP-IP2 Rmax 2
E9
APP-IP3 Speed 1
E17
APP-IP4 Speed 2
E5
APP-IP5 Reverse droop
E6
APP-IP6
E13
APP-IP7 Rmax 1
E20
APP-OP1 Starter relay
E2
APP-OP2 Eco-mode lamp Block heater relay
Contact input terminal switches are available in two types: NC (normally closed) and NO (normally open).
Table 2-15 lists contact input terminals for which a NO or NC switch can be selected.
Table 2-15 Contact input terminal switches available in NC and CO types
Terminal
Terminal
No.
name
E24
APP-IP1
E14
APP-IP2
E9
APP-IP3
E17
APP-IP4
E5
APP-IP5
E6
APP-IP6
E13
APP-IP7
E15
SHUDNSW Engine stop
2-62
Table 2-14 E-ECU terminals assigned multiple functions
Function 1
(default)
Oil pressure switch
Charge alarm
Coolant temperature
switch
Air cleaner
Speed selection
Oily water separator
enable
Stop 2 switch
Middle-speed lamp
Default function
Droop selection
Rmax 2
Speed 1
Speed 2
Reverse droop
Speed selection enable
Rmax 1
Function 2
-
Speed up
-
-
Machine (up)
Machine (down)
-
-
Speed change
indication lamp
Function 3
Function 4
-
Foot pedal NO switch
-
-
Pulse accelerator
-
Foot pedal NC switch
-
Coolant temperature
alarm lamp
Default input logic
NC
NO
NO
NO
NO
NO
NO
NO