Hyundai Yanmar TNV Series Manual page 30

For epa tier3
Table of Contents

Advertisement

Operating conditions
Table 2-1 shows the operating conditions of the E-ECU.
Rated voltage
Operating ambient temperature
Storage ambient temperature
Operating voltage range
Minimum operating voltage
Vibration
Severity level
The acceleration, speed and displacement of the E-
ECU mount must conform to the requirements
shown to the right in an overall range of 5 - 1000 Hz.
Waterproofness (of connector)
Precautions:
• IInstall the E-ECU in a location that is not subject to steam or high-pressure water for cleaning.
• Install the E-ECU in a location that is well ventilated and not subject to direct sunlight.
• Install the E-ECU so that the connector faces downward. Failure to do so may trap water in the connector,
resulting in corrosion of connector pins.
• Do not plug or unplug the connector for at least 6 seconds after the E-ECU is turned on or off.
• Do not touch connector pins with bare hands. Doing so may corrode or statically charge connector pins,
resulting in damage to electronic components in the E-ECU.
• Do not force a measuring or testing probe into the female coupler of the connector. Doing so may cause
contact failure of connector pins, resulting in malfunction of the E-ECU.
• Ensure no water is trapped inside the coupler when plugging or unplugging the connector. Water inside
the coupler may corrode connector pins, resulting in malfunction of the E-ECU.
• Avoid plugging/unplugging the connector more than ten times. Repeated plugging/unplugging may
cause contact failure of connector pins, resulting in malfunction of the E-ECU.
• Do not use the E-ECU that has suffered drop impact.
• When the machine is used in areas where a cryoprotectant/salt is distributed or near the seashore, the
aluminum case of the E-ECU may corrode, resulting in malfunction of the E-ECU. Use a cover to protect
the E-ECU against salt intrusion.
TNV Application Manual
Table 2-1 Operating conditions of the E-ECU
Item
CONTROL SYSTEM
Requirement
12 Vdc
-30°C ~ 80°C
-40°C ~ 110°C
10.0 – 16.0 Vdc
6.0 Vdc Min.
To be installed on a place of 45 or lower in
severity level
2
Acceleration:70.4 m/s
Speed:44.6 mm/s (rms) Max.
Displacement:0.283 mm (rms) Max.
0.800 mm (p.p) Max.
• JIS D0203 S2 compliant
• The E-ECU must not be installed with its
connector facing upward.
(rms) Max.
2-11

Hide quick links:

Advertisement

Table of Contents
loading