(2) Constant deceleration mode
Figure 2-41 shows the connection diagram for constant deceleration mode.
Figure 2-41 Connection diagram for constant deceleration mode
Figure 2-42 shows the operation timing for constant deceleration mode. The speed selection enable switch
(E6) is available in two types: toggle and momentary.
Speed selection enable
APP-IP6
Operation
Speed selection enable
APP-IP6
Operation
TNV Application Manual
Batt.12V
E48
APP-OP2(E2)
APP-IP6(E6)
ECU
APP-IP4(E17)
APP-IP3(E9)
E45,E47
2: Constant deceleration mode (lock switch)
Via input terminals APP-IP3/APP-IP4
3: Constant deceleration mode (one-touch switch)
Via input terminals APP-IP3/APP-IP4
Figure 2-42 Operation timing for constant deceleration mode
Indicator lamp
Speed1
Speed2
Speed selection enable
CONTROL SYSTEM