Hyundai Yanmar TNV Series Manual page 127

For epa tier3
Table of Contents

Advertisement

3)Data Set sub-window
:Shows the name of an item for which active control is enabled.
Data Name
:Displays the current measured value of the feedback item.
Measured
:Shows the maximum value that can be set for the desired value.
Max
:Shows the current setting value(desired value) .
Desired
:Shows the minimum value that can be set for the desired value.
Min
:Note.
Note
/
:Increases/decreases the setting value with one of the factors:1, 10, or 100.
:Restores the factory settings.
Default
:Selects whether to receive feedback data.
Reception Mode
/
:Increases/decreases the Receiving Time value.
:Outputs the set data to the ECU.
Set
:Cancels the set data and closes the sub-window.
Close
 ・ To control the selected item manually, increase/decrease the current value with the UP/DOWN
buttons and press the Set button.
 ・ When graph display mode is selected, you can receive feedback data at the set time and view it on the
graph screen. Note that, the data is meaningless when the auto tuning function is enabled.
Figure 7-11 [Diagnostic Test]-[Active Control]-[Data Set]Sub-Window Screen
7. Main Menu ――
27