CONTROL SYSTEM
Assignment flag
APS: E35
3
4
-
To connect the accelerator position sensor input (APS: E35) and the backup analog sensor input (REAN:
E7) to the foot pedal (flag setting: 2 - 4), APP-IP2: E14 and APP-IP7: E13 must be configured to enable
reception of signals from the foot pedal switch. In addition, APP-IP2: E14 and APP-IP7: E13 must be
configured to enable connection with an NO switch and NC switch respectively. (Set APP-IP2 to NO and
APP-IP7 to NC. See Table 2-15. When the flag is set to 2, APP-IP2 and APP-IP7 must be set to NO and NC
respectively. When the flag is set to 3, APP-IP2 must be set to NO. When the flag is set to 4, APP-IP7 must
be set to NC).
Figure 2-33 shows the foot pedal operation and engine speed. When the flag is set to 2, the input voltage at
terminal APS or REAN is effective only when APP-IP2: NO is low and APP-IP7: NC is high. Otherwise, the
engine runs at low idling speed.
When the flag is set to 3, the input voltage at terminal APS or REAN is effective only when APP-IP2: NO is
low. Otherwise, the engine runs at low idling speed.
When the flag is set to 4, the input voltage at terminal APS or REAN is effective only when APP-IP7: NC is
high. Otherwise, the engine runs at low idling speed.
When two foot pedals are used, APS: E35 and REAN: E37 must be flagged to 3 and 4 (or vice versa)
respectively.
E-ECU
5V
ADC
12V
12V
2-44
Table 2-9 Analog input assignment
REAN: E37
3
4
5
AVCC (E38)
APS (E35)
REAN (E37)
GND-A (E28)
1.2k
APP-IP2 ( E14)
NO
1.2k
NC
APP-IP7 ( E13)
Figure 2-33 Foot pedal operation
Foot pedal (SAE J1843 configuration)
Analog + APP-IP2: NO
Foot pedal (SAE J1843 configuration)
Analog + APP-IP7: NC
Atmospheric pressure sensor
Accelerator sensor
or
Backup accelerator sensor
NO:E14
Switch state
NC:E13
【Pattern1】
【Pattern2】
【Pattern3】
Sensor type
High idling
3.0
Low idling
0.7
0
Input voltage [V]
5.0
Accel. sensor available
: NC=High & NO=Low
Accel. sensor available
: NO=Low
Accel. sensor available
: NC=High
(Other switch state : Low idle speed)