3)Additional Information view
(i)Trigger Setting
Displays trigger setting information.
①
Manual Trigger
②
:Displays the trigger setting status.
Trigger
③
:Displays the acronym of data for which a trigger is set.
Data
④
:Displays the threshold value of the trigger setting.
Level
⑤
:Displays the type of the set trigger(rising edge or falling edge) .
Type
⑥
:Shows the number of data points between the start of storage and the trigger.
Delay
⑦
: Shows the number of data points to be stored(a single point means a set of data items
Storage
at a certain point of time) .
(ii)Preservation status
Displays the data logging status.
⑧
: Displays the status:"Display" during waiting for a trigger, "Preservation" during storing
Status
data, or "Completion" at the completion of measurement.
⑨
:Displays the number of acquired data points.
Counter
⑩
:Displays the time when monitoring starts.
Mon. Start
⑪
:Displays the elapsed time from the start of measurement.
Run
⑫
:Displays the remaining time until the end of measurement.
Rest
(iii)Sampling setting
Displays the sampling setting status.
⑬
: Displays "Intermittence" when the sampling frequency setting is 100 msec or "Polling" for
Mode
other settings.
⑭
:Displays the sampling frequency.
Interval
:Lets you generate a trigger manually.
Figure 7-16 [Data Logging]-[Data Monitor]Screen
7. Main Menu ――
①
②
③
④
⑤
⑥
⑦
⑧
⑨
⑩
⑪
⑫
⑬
⑭
33