Mitsubishi Electric Melservo MR-J5 Series User Manual page 33

Hide thumbs Also See for Melservo MR-J5 Series:
Table of Contents

Advertisement

■Encoder cable 3 (two-wire type)
Connector set (optional)
MR-J3CN2
Receptacle: 36210-0100PL
Shell kit: 36310-3200-008
(3M)
2
6
10
LG
4
8
THM2
MRR
1
5
9
P5
3
7
THM1
MR
*3
View from the wiring side.
or
Connector set: 54599-1019
(Molex)
2
4
6
8
10
LG
MRR
THM2
1
3
5
7
9
P5
MR
THM1
*3
View from the wiring side.
*1 Encoder cables that meet the following specifications are recommended.
Wiring length
to 5 m
to 10 m
to 20 m
to 30 m
*2 For wiring to the thermistor of the linear servo motor, "Power cable wiring diagram" in the following manual.
Linear Servo Motor User's Manual
*3 Do not connect anything to the pins shown with a diagonal line. Securely connect the external conductor of the shielded cable to the
ground plate and fix it to the connector shell.
Page 4 Shield procedure of CN2, CN2A, CN2B, and CN2C side connectors
Servo amplifier-side
Plate
SD
*1
P5
1
LG
2
MR
3
MRR
4
THM1
5
THM2
6
AWG 24 to 20
Number of LG and P5 connections
1-pair
2-pair
3-pair
4-pair
Linear encoder-side
FG
4
5 V
2
0 V
12
5 V/sensor
10
0 V/sensor
8
RQ, SD
15
/RQ, /SD
Connector: D-SUB (female) 15 pin
Thermistor of linear servo motor
1.4 Linear encoder manufactured by Heidenhain
*2
Wire size
AWG 22
1 LINEAR ENCODER
31