DO NOT DISCARD - GIVE THIS MANUAL TO THE OWNER AFTER INSTALLATION
● Installation must conform to all local plumbing codes and regulations.
● Do NOT use with water that is microbiologically unsafe or of unknown quality without adequate
disinfection before or after the system. Systems certified for cyst reduction may be used on
disinfected waters that may contain filterable cysts.
● Connect system to cold water supply only! Water temperature must not exceed 100°F/38°C.
● Do NOT solder plumbing connections attached to the assembly. High temperature will damage
these components.
● Do NOT over-tighten fitting connections. Always back-up valves and fittings with a wrench to
avoid turning the valve.
● Allow a minimum of 3" under the housing to allow for sump removal and filter replacement.
● Do NOT mount the system near a heat source or above the electrical wiring or any device or
area that would be adversely affected by water.
● Do NOT mount the system behind equipment. The unit must be easily accessible for filter
replacement.
● Failure to change cartridges per recommended intervals with OptiPure replacement cartridges
may lead to system failure and property damage.