MTS Systems Temposonics GB Series Brief Instructions page 10

Magnetostrictive linear position sensors
Table of Contents

Advertisement

Temposonics
GB-Series
®
Brief Instructions
D60 (for outputs: V0, A0, A1, A2, A3 in order code)
Signal + power supply
M16 male connector
Pin
1
2
1
3
2
6
5
3
4
4
5
View on sensor
6
* Connection necessary for programming with hand or cabinet
programmer
D60 (for output: A4 in order code)
Signal + power supply
M16 male connector
Pin
1
2
1
3
2
6
5
3
4
4
5
View on sensor
6
* Connect the fi rst output (4...20 mA) at low-resistance,
if you only use the second output (20...4 mA)
Voltage
Current
4(0)...20 mA or
0...10 VDC
20... 4(0) mA
DC Ground
DC Ground
10...0 VDC
Not connected
DC Ground
DC Ground
+24 VDC
+24 VDC
(−15 / +20 %)
(−15 / +20 %)
DC Ground (0 V)
DC Ground (0 V)
Current
4...20 mA
*
DC Ground
20...4 mA
DC Ground
+24 VDC (−15 / +20 %)
DC Ground (0 V)
HXX / TXX / VXX (for outputs: V0, A0, A1, A2, A3 in order code)
Signal + power supply
Cable
*
* Connection necessary for programming with hand or cabinet
programmer
HXX / TXX / VXX (for output: A4 in order code)
Signal + power supply
Cable
* Connect the fi rst output (4...20 mA) at low-resistance,
if you only use the second output (20...4 mA)
NOTICE
DANGER OF SHORT-CIRCUIT!
Insulate the conductors of the second output (yellow,
green), if you only use the first output. We recommend
providing terminals for the second output in the
control cabinet, since the leads are required for sensor
programming.
I
10
I
Color Voltage
Current
4(0)...20 mA or
GY
0...10 VDC
20... 4(0) mA
PK
DC Ground
DC Ground
YE
10...0 VDC
Not connected
GN
DC Ground
DC Ground
+24 VDC
+24 VDC
BN
(−15 / +20 %)
(−15 / +20 %)
WH
DC Ground (0 V)
DC Ground (0 V)
Color Current
GY
4...20 mA
*
PK
DC Ground
YE
20...4 mA
GN
DC Ground
BN
+24 VDC (−15 / +20 %)
WH
DC Ground (0 V)
*