Container pressure too low / Operating pressure in the system too low
Possible cause of failure
Pressure difference of the inlet filter is too high
The compressed-air system upstream of the
activated-carbon adsorber is pressureless
Larger amounts of wear debris in the system:
clogged compressed-air distributor or filter
elements
NOTE!
In the event of malfunctions which are not listed here or which cannot be eliminated, please
contact BEKO TECHNOLOGIES GMBH.
CLEARPOINT® L 205 – L295 V
Troubleshooting and fault elimination
Fault elimination
Check the pressure drop via the inlet filter
Replace the filter element, if required
Check the compressed-air system
upstream of the activated-carbon adsorber
Eliminate any faults
Replace the dust filter element
Replace the activated carbon
Clean the compressed-air distributor
Verify the operating conditions (pulsation,
volume flow)