Technical data
10 Technical data
10.1 Technical data CLEARPOINT
Name
Manufacturer
Type
Medium
Minimum ambient temperature
Maximum ambient temperature
Maximum air volume flow at the inlet
Minimum compressed-air inlet temperature
Maximum compressed-air inlet temperature
Recommended compressed-air inlet temperature
Recommended residual humidity of the
compressed air at the inlet
Minimum operating pressure
Max. permissible operating overpressure L 205-
275 V
Max. permissible operating overpressure L 295 V
Recommended operating pressure
Residual oil content at the outlet
Adsorbent
Service life at nominal performance data and
reference conditions
Compressed-air connection
Height x width x depth approx.
Weight approx.
Category acc. to PED 97/23/EC – fluid group 2
Design data pressure vessel
Design pressure L 205-275 V
Design pressure L 295 V
Design temperature
Test pressure hydraulic L 205-275 V
Test pressure hydraulic L 295 V
Design and construction
*
The service life of the activated-carbon adsorber is reduced when this value is exceeded
18
®
L 205-295 V
CLEARPOINT
BEKO TECHNOLOGIES GMBH
Germany,
41468 Neuss, Im Taubental 7
Activated-carbon adsorber
Compressed air
Saturated up to 30%
Free from water or condensate
Free from aggressive or corrosive
components
+5°C
+50°C
See table
+2°C
+50°C
+35°C*
< 30%*
4 bar(g)
16 bar(g)
11 bar(g)
7 bar(g)
max. 0.003 mg/m³
Activated carbon type 1
Approx. 10,000 operating hours
See table
See table
See table
See table
16 bar(g)
11 bar(g)
-10 / +50°C
22.9 bar(g)
15.8 bar(g)
Acc. to PED 97/23/EC and AD-2000
®
L 205-295 V
CLEARPOINT® L 205 – L295 V