Technical Data; Technical Data Clearpointl - Beko CLEARPOINT Series Instructions For Installation And Operation Manual

Activated-carbon adsorber without dust filter
Hide thumbs Also See for CLEARPOINT Series:
Table of Contents

Advertisement

Technical data

10 Technical data
10.1 Technical data CLEARPOINT
Name
Manufacturer
Type
Medium
Minimum ambient temperature
Maximum ambient temperature
Maximum air volume flow at the inlet
Minimum compressed-air inlet temperature
Maximum compressed-air inlet temperature
Recommended compressed-air inlet temperature
Recommended residual humidity of the
compressed air at the inlet
Minimum operating pressure
Max. permissible operating overpressure L 205-
275 V
Max. permissible operating overpressure L 295 V
Recommended operating pressure
Residual oil content at the outlet
Adsorbent
Service life at nominal performance data and
reference conditions
Compressed-air connection
Height x width x depth approx.
Weight approx.
Category acc. to PED 97/23/EC – fluid group 2
Design data pressure vessel
Design pressure L 205-275 V
Design pressure L 295 V
Design temperature
Test pressure hydraulic L 205-275 V
Test pressure hydraulic L 295 V
Design and construction
*
The service life of the activated-carbon adsorber is reduced when this value is exceeded
18
®
L 205-295 V
CLEARPOINT
BEKO TECHNOLOGIES GMBH
Germany,
41468 Neuss, Im Taubental 7
Activated-carbon adsorber
Compressed air
Saturated up to 30%
Free from water or condensate
Free from aggressive or corrosive
components
+5°C
+50°C
See table
+2°C
+50°C
+35°C*
< 30%*
4 bar(g)
16 bar(g)
11 bar(g)
7 bar(g)
max. 0.003 mg/m³
Activated carbon type 1
Approx. 10,000 operating hours
See table
See table
See table
See table
16 bar(g)
11 bar(g)
-10 / +50°C
22.9 bar(g)
15.8 bar(g)
Acc. to PED 97/23/EC and AD-2000
®
L 205-295 V
CLEARPOINT® L 205 – L295 V