Troubleshooting and fault elimination

15.2 Status and alarm indications

Residual oil content too high
Possible cause of failure
Inlet volume flow too high
Operating pressure too low
Compressed-air temperature at the inlet too high
Inlet filter elements exhausted
Pressure difference too high
Use of oil-contaminated filters or filter elements
downstream of the activated-carbon adsorber
Oil-contaminated circuit sections between the
activated-carbon adsorber and the measuring
point
Condensate drainage upstream of the activated-
carbon adsorber does not work
Max. absorption capacity of the activated carbon
reached
38
Fault elimination
Reduce the inlet volume flow
Increase the operating pressure
Reduce the compressed-air temperature
at the inlet
Install a precooler, if required
Replace the inlet filter elements
Use of BEKO filters and filter elements in
an oil- and grease-free version
Clean the pipesection or install a new
pipesection
Check the functioning of the condensate
drain (at the inlet filter), repair or replace it,
if required
Replace the activated carbon