Zennio MAXinBOX 66 Manual page 25

Multifunction actuator with 6 outputs and 6 inputs
Hide thumbs Also See for MAXinBOX 66:
Table of Contents

Advertisement

211, 241, 271, 301
212, 242, 272, 302
213, 243, 273, 303
214, 244, 274, 304
215, 245, 275, 305
216, 246, 276, 306
217, 247, 277, 307
218, 248, 278, 308
309
310, 311, 312, 313, 314, 315, 316, 317, 318, 319,
320, 321
322
323
324
325
326
327
328
329
330
331, 335, 339, 343, 347, 351
http://www.zennio.com
1 Byte
O
C T R - -
DPT_Scaling
1 Byte
O
C T R - -
DPT_Scaling
1 Bit
O
C T R - -
DPT_Switch
1 Bit
O
C T R - -
DPT_Switch
1 Bit
O
C T R - -
DPT_Switch
1 Bit
O
C T R - -
DPT_Switch
1 Bit
O
C T R - -
DPT_Switch
1 Bit
O
C T R - -
DPT_Switch
1 Bit
O
C T R - -
DPT_Switch
1 Bit
O
C T R - -
DPT_Switch
1 Bit
I
C - - W -
DPT_Switch
1 Bit
I
C - - W -
DPT_Switch
1 Bit
O
C T R - -
DPT_Switch
1 Bit
C T - - -
DPT_Switch
1 Byte
C T - - -
DPT_Scaling
1 Byte
C T - - -
DPT_SceneControl
1 Byte
C T - - -
DPT_HVACMode
1 Bit
C T - - -
DPT_Switch
1 Byte
C T - - -
DPT_Scaling
1 Byte
C T - - -
DPT_SceneControl
1 Byte
C T - - -
DPT_HVACMode
2 Bytes
O
C T R - -
DPT_Value_Temp
0% - 100%
[Tx] Control Variable (Cool)
0% - 100%
[Tx] Control Variable (Heat)
0/1
[Tx] Control Variable (Cool)
0/1
[Tx] Control Variable (Cool)
0/1
[Tx] Control Variable (Heat)
0/1
[Tx] Control Variable (Heat)
0/1
[Tx] Additional Cool
0/1
[Tx] Additional Heat
0/1
[Tx] PI State (Cool)
0/1
[Tx] PI State (Heat)
0/1
[ML] Trigger
0/1
[ML] Status Object X
0/1
[ML] General Status
[ML] General Switch Off:
0/1
Binary Object
[ML] General Switch Off:
0% - 100%
Scaling
[ML] General Switch Off:
0-63; 128-191
Scene
1=Comfort
2=Standby
[ML] General Switch Off: HVAC
3=Economy
mode
4=Building Protection
[ML] Courtesy Switch On:
0/1
Binary Object
[ML] Courtesy Switch On:
0% - 100%
Scaling
[ML] Courtesy Switch On:
0-63; 128-191
Scene
1=Comfort
2=Standby
[ML] Courtesy Switch On:
3=Economy
HVAC mode
4=Building Protection
-273.00 - 670760.00
[Ix] Current Temperature
Technical Support:
MAXinBOX 66
PI Control (Continuous)
PI Control (Continuous)
2-Point Control
PI Control (PWM)
2-Point Control
PI Control (PWM)
Temp >= (Setpoint+Band)
=> "1"
Temp <= (Setpoint-Band)
=> "1"
0 = PI signal 0%; 1 = PI
signal greater than 0%
0 = PI signal 0%; 1 = PI
signal greater than 0%
Trigger the Master Light
Function
Binary Status
Binary Status
Switch Off Sending
0-100%
Scene Sending
Auto, Comfort, Standby,
Economy, Building
Protection
Switch On Sending
0-100%
Scene Sending
Auto, Comfort, Standby,
Economy, Building
Protection
Temperature sensor value
http://support.zennio.com
25

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MAXinBOX 66 and is the answer not in the manual?

Table of Contents