Troubleshooting

Fault
LED on the readhead is Blank
LED on the readhead is Red and
I can't get a Green LED
Unable to get a flashing Green LED
around the full axis of rotation
Can't initiate the calibration routine
LED on the readhead remains single
flashing Blue even after moving it
around the full axis of rotation
ATOM DX
rotary installation guide
Cause
There is no power to the readhead
The signal strength is <50%
System run-out is not within specification
Signal size is <70%
The system has failed to calibrate the
incremental signals due to the signal
strength being <70%
Possible solutions
Check you have 5 V at the readhead
u
For cable variants check correct wiring of connector
u
Check the readhead optical window and disc are clean and free from contamination
u
Restore factory defaults
(see page 12)
and check alignment of the readhead. In particular;
u
– Rideheight
– Longitudinal and radial offset
Check the disc and readhead orientation
u
Check that the readhead variant is the correct type for the chosen disc
u
(see the ATOM DX data sheet (L-9517- 9736) for details of readhead configuration)
Check that the readhead variant is the correct type for the chosen disc
u
(see the ATOM DX data sheet (L-9517- 9736) for details of readhead configuration.
Use a DTI gauge and check the run-out is within specifications
u
Restore factory defaults
u
Realign readhead to obtain a Green LED at the mid-point of the run-out
u
Recalibrate the system
(see page 12)
u
Restore factory defaults
u
u
Realign readhead to obtain a Green flashing LED
Exit CAL mode and restore factory defaults
u
Check system set-up and realign the readhead to obtain a flashing Green LED around the full axis of rotation
u
before recalibrating
(see page 12)
13