Checklist for commissioning naturally cooled 1FW6 built-in torque motors
Before starting any work, get to know and understand the safety notes and observe the
following checklists.
Table 6- 1
Are all of the necessary components of the configured drive line-up available, correctly
dimensioned, installed and connected?
Are the manufacturer documentation for the system components (e.g. drive system,
encoder, cooling system, brake) and the Configuration Manual "Naturally cooled
SIMOTICS T-1FW6 built-in torque motors" available?
If the 1FW6 built-in torque motor is to be fed from a SINAMICS S120 drive system:
Is the following, current SINAMICS documentation available?
If the 1FW6 built-in torque motor is to be fed from a SINAMICS S120 drive system:
Was the Chapter "Checklists for commissioning SINAMICS S" in the SINAMICS S120
Commissioning Manual carefully observed?
Is the motor type to be commissioned known?
(e.g. 1FW6 _ _ _ – _ _ _ _ _ – _ _ _ _)
If the motor is to be fed from a SINAMICS S120 drive system:
If it involves a "third-party motor", are the following motor data known as a minimum?
(A "third-party motor" is a motor that is not saved as standard in the Siemens
commissioning software.)
Are the environmental conditions in the permissible range?
82
Checklist (1) – General checks
SINAMICS S120 Commissioning Manual
Getting Started S120
S120 Function Manual
S120/150 List Manual
Rated motor current
Rated motor speed
Motor pole pair number
Motor torque constant
Maximum motor speed
Maximum motor current
Motor limit current
Motor moment of inertia
Motor stator resistance, cold
Motor stator leakage inductance
Check
Naturally cooled 1FW6 built-in torque motors
Operating Instructions, 07/2017, 6SN1197-0AF02-0BP2
OK