Siemens SIMOTICS-T 1FW6053-B05-0F Operating Instructions Manual page 22

Naturally cooled built-in torque motors
Table of Contents

Advertisement

Description
2.1 Use for the intended purpose
Danger to life for wearers of active implants due to magnetic and electrical fields
Electric motors pose a danger to people with active medical implants, e.g. cardiac
stimulators, who come close to the motors.
• If you are affected, stay a minimum distance of 300 mm from the motors (tripping
In conjunction with a suitable drive system, the built-in torque motors can be used as direct
drive for the following machine applications:
● Roller and cylinder drives
● Swiveling axes in measuring machines and medical equipment
● Feed and handling axes
● Rotary tables and sub-machine assemblies
● Tool revolvers
Personal injury and material damage by noncompliance with directive 2006/42/EC
There is a risk of death, serious injury and/or material damage if Directive 2006/42/EC is
not carefully observed.
• The products included in the scope of delivery are exclusively designed for installation in
• Please take into account all safety instructions and provide these to end users.
Please take note of national and international license terms when operating direct motors so
that no patent rights are violated.
Note
Note that when 1FW6 direct motors (torque motors) are used in fork heads for machine tools
or robots, a license for US patent US5584621 and the associated international patent
protection may be required.
22
WARNING
threshold for static magnetic fields of 0.5 mT according to the Directive 2013/35/EU).
WARNING
a machine. Commissioning is prohibited until it has been fully established that the end
product conforms with Directive 2006/42/EC.
Naturally cooled 1FW6 built-in torque motors
Operating Instructions, 07/2017, 6SN1197-0AF02-0BP2

Advertisement

Table of Contents
loading