Attention: Removing a device from the network means that it is turned back into factory
default status. This process can also exclude devices from it's previous network.
For Exclusion of Z-Wave devices from the thermostats network do the following steps: Set
DIL switch 1 on the back of the unit to "ON" position, scroll through the function menu by
rotating the dial, select "E". Press the dedicated button on the target device to exclude it. Once
the character starts flashing the installer has 60 sec to activate the 3rd party unit, once the 3rd
party unit has been activated the process must be completed within 240 sec or the thermostat
will timeout.
Shift of Primary Controller Role
The device can hand over its primary role to another controller and become secondary
controller.
Set DIL switch 1 on the back of the unit to "ON" position, scroll through the function menu
by rotating the dial, select "C". The thermostat will become the secondary controller.
Management of Association in the controller
To assign associations with devices you wish to control with the thermostat do the following
steps: Set DIL switch 1 on the back of the unit to "ON" position, scroll through the function
menu by rotating the dial, select "A". Press the dedicated button on the target device you wish
to control.
To disassociate an association do the following steps: Set DIL switch 1 on the back of the unit
to "ON" position, scroll through the function menu by rotating the dial, select "D". Press the
dedicated button on the target device you wish to disassociate.

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain
configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values
in the range 128 ... 255 the value sent in the application shall be the desired value minus 256.
For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 =
minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.
Parameter 1: Enables Temperature Sensor
controls the use of the temperature sensor on the device
Size: 1 Byte, Default Value: 0
Setting
Description
0 - 127
Disable
128 - 255 Enabled